Error and System Messages
Appendix B
B-41
Message Description
SPINDLE IS CLAMPED An attempt was madetoprogramablockcontainingaspindlecode otherthanan M05 while the
PALservo clamprequest flagfor thespindle was set.
SPINDLE MODES INCOMPATIBLE An attemptwas made toentervirtual modewhen the spindle thatis usedforthismodeis
synchronized as thefollowerspindle oranattemptwasmade toperform end facemillingduring
synchronization.
SPINDLE MOTOR SPEED TOO HIGH When using a 1326 motoras a spindle,feedback resolutioncombined withyour configured
maximumspindlespeed would returnfeedbackcountsfasterthan thecontrolcanreliably
decode. Eitherreduce themaximum configuredspindle speed, orreducethe configured
feedbackcountsfor thespindle in AMP.
SPINDLE MUST BE THE LAST SERVO When the systemi s AMPed,the spindle must be assigned to the firstavailable portafter all axes
havebeenassigned.
SPINDLE NOT ASSIGNED Aspindle axis was AMPed, but notassigned toanyprocess.
SPINDLEORDERERROR,AMPAUX.2 SECOND AMP order ofspindles mustbe primaryspindle, aux.spindle 2,aux.spindle 3.
SPINDLEORDERERROR,AMPAUX.3 THIRD AMPorder ofspindles mustbe primaryspindle,aux.spindle 2,aux.spindle 3.
SPINDLE ORDER ERROR, AMPPRIMARY 1ST AMPorder ofspindles mustbe primaryspindle, aux.spindle 2,aux.spindle 3.
SPINDLESYNC NOT CONFIGURED T he programmerattempted to entersynchronizedspindle mode beforeit was configured in
AMP.
SPINDLE SYNC UNAVAILABLE THIS PROCESS An attemptwas madetoenter synchronized spindle mode on a dual--processcontrol when the
processwas notyet configured forboth spindlesin the synchronized pair.
SQUARERO OT OF NEGATIVEERROR Internalmath errorhas occurred;contactAllen-Bradleycustomersupportservices.
SQUARERO OT OF NEGATIVEINVALID An attemptwas madetodeterminethesquare rootof a negativenumber usingthecalculatoror
througha paramacroSQRT command.
STORED PASSWORD LIST TO BACKUP This messageappears afterthepasswordlisthas been successfullystored to thecontrol’s
backupmemory.
STORING TO BACKUP - PLEASE WAIT T his messageappears wheneverAMPoraxis calibrationdata in RAMis being storedin backup
memory.
SYMBOL NAME FORMAT ERROR Checkthe remotesymbolandCNCsymbol tomake surethey existon both remote and CNC.
Checkthe tableofthe readonlyorwrite onlyvariables.
SYMBOL NOT FOUND Checkthe remotesymbol and CNC symbol tomake surethey existon both remote and CNC.
Checkthe tableofthe readonlyorwrite onlyvariables.
SYNCHRONIZATIONDEADLOCK Asynchronization code is activated and caused theactivatingprocessto waitonaprocess that
isalreadywaiting.
SYNCH SPINDLES MISCONFIGURED Causesfor thiscould be: onlyonespindle(eithercontrollingorfollower)wasdefined in the
synchronizedspindle pair, youexceeded thesimple feedbackratiolimitationof 10 (e.g., 11:1 or
2:13), or on a multiprocess system, one (or both) ofthe spindles in the synch pair iscurrently not
availabletothe processmakingthesynchronization request.
SYNCH SPINDLES REQUIRE FEEDBACK One orbothof thespindles,configuredinAMPasamemberofasynchronized pair,didnot
havefeedback. Bothspindles in a synchronized pair mustbe equipped with an AMPconfigured
feedbackdevice.
SYNTAXERROR (COMMA) Amissingcomma or an extracomma wasfoundin the programblock.
SYSTEM DIAGNOSTIC #1 An illegal parameterwas passedi nto a switchstatement(mid-programstart) in the control
software. ContactAllen-Bradleycustomer supportservices.
SYSTEM DIAGNOSTIC #2 An illegal parameterwas passedi nto a switchstatement(ASCIIbuffer task) in the control
software. ContactAllen-Bradleycustomer supportservices.
SYSTEM DIAGNOSTIC #3 An illegal parameterwas passedi nto a switchstatement(ASCIIbuffer task) in the control
software. ContactAllen-Bradleycustomer supportservices.