Displays and Graphics
Chapter 8
8-3
3. To return to softkey level 1, press the [DISP SELECT] key again. The
most recently selected data position screen will remain in effect for
softkey level 1 until either power is turned off or a different position
display screen is selected. The default screen selected at power up is
the regular size program display.
The following figures show the axis position data display that will result
when the corresponding softkey is pressed.
{PRGRAM}
Axis position in the current work coordinate system displayed in normal
size characters.
Figure 8.1
Result Af ter Pressing {PRGRAM} Softkey
PRGRAM ABS TARGET DTGAXIS
SELECT
PROGRAM[ MM ] F 0.000 MMPM
X -7483.647 S 00
Z -7483.647 T 0
U -7483.647 (ACTIVE PROGRAM NAME)
MEMORY MAN STOP
E-STOP