98 Rockwell Automation Publication 2098-UM001G-EN-P - February 2011
Chapter 3 Configuring the Ultra3000 Drive
The following status is displayed by default for an Ultra3000 drive in the Digital
Inputs window:
No commands are associated with the Digital Inputs window.
Customize the Digital Inputs window for your Ultra3000 Drive by selecting one
or more of these commands:
Click Show Status to display or hide the Status pane.
Click Setup to open the Monitor Setup window as shown on page 105
,
where you can customize the status display for this window.
Click Revert to return parameter settings to the values they held when you
opened this window.
Reverse Enable: An active state permits reverse motion.
Start Homing: A transition to an active input state causes the to
initiate the homing routine.
Start Indexing: A transition to an active input state begins an
indexing move.
Stop Homing: A transition to an active state terminates a
homing sequence.
Stop Indexing: A transition to an active state terminates an
indexing move.
Note: The Input value displays Not Assigned if there is nothing selected, Multiple if there are
multiple functions selected, or the name of the function if only one is selected.
Status Description
Input 1 – 8 State The current state, or condition, of each digital input is depicted
by a light bulb icon, as follows:
ON: a bright light bulb
OFF: a darkened light bulb.
Parameter Description