118 Rockwell Automation Publication 2098-UM001G-EN-P - February 2011
Chapter 3 Configuring the Ultra3000 Drive
Understanding Ultra3000
Status
The following Ultra3000 drive status settings can be displayed in the Monitor
window and can be assigned as an Input Signal for a Channel in the Oscilloscope
window as indicated in the table:
Status Description Non-SERCOS
Drive
SERCOS Drive
Scope Monitor Scope Monitor
Drive Status
Analog Command
In
Refer to
Understanding the
Analog Window on page 59
XX
Brake Refer to Understanding the
Digital Outputs Window on
page 99
XXXX
Bus Voltage Refer to
Understanding the
Ultra3000 Drive Branch on
page 41
XXXX
Disable Serial
Communications
Refer to Understanding the
Digital Inputs Window on page
95
XX
Drive Enabled Refer to Understanding the
Ultra3000 Drive Branch on
page 41
XXXX
Drive Temperature Reports the percentage of the
Drive Temperature Trip value,
that is based on the drives
continuous current rating and
time. The Drive Temperature is
an indication of the level of
utilization of the drive's
current capability. When the
Drive Temperature reaches
100%, the IPM Fault occurs.
XXXX
Fault State Indicates Drive Ready if the
drive is not faulted, or
indicates the first fault that
occurred to take the drive out
of a normal operating mode.
XX
Firmware Version Refer to
Understanding the
Service Information Window
on page 135
XX
Forward Enable Refer to
Understanding the
Digital Inputs Window on page
95
XX
Motor Temperature Reports the percentage of the
Motor Temperature Trip value,
that is based on the motors
continuous current rating,
thermal characteristics, and
time. The Motor Temperature
is an indication of the level of
utilization of the motor's
current capability. When the
Motor Temperature reaches
100%, the Motor Filter fault
occurs.
XXXX
Operating Mode Refer to
Operation Modes on
page 42
X
Zobrazit stránku 115