88 Rockwell Automation Publication 2098-UM001G-EN-P - February 2011
Chapter 3 Configuring the Ultra3000 Drive
The following status is displayed by default for an Encoders window of an online
drive:
The following commands can be executed on an online drive using the Encoders
window:
Customize the Encoders window for your Ultra3000 Drive by selecting one or
more of these commands:
• Click Show Status to display or hide the Status pane.
• Click Show Commands to display or hide the Commands pane.
• Click Setup to open the Monitor Setup window as shown on page 105
,
where you can customize the status display for this window.
• Click Revert to return parameter settings to the values they held when you
opened this window.
Status Description
Motor Encoder
Position – Motor Feedback Actual motor position (in selected units).
Encoder Temperature Measured temperature of the motor encoder in degrees C.
Note: This parameter is visible only if the Auto Motor Iden is
enabled.
A A input channel of the motor encoder
B B input channel of the motor encoder
Z Z input channel of the motor encoder
S1 Hall input S1 of the motor encoder
S2 Hall input S2 of the motor encoder
S3 Hall input S3 of the motor encoder
Auxiliary Encoder
Position – Auxiliary Actual auxiliary encoder position (in selected units).
A A input channel of the auxiliary encoder
B B input channel of the auxiliary encoder
Z Z input channel of the auxiliary encoder
Command To
Commutation Diagnostics Verify motor commutation
Motor Feedback Diagnostics‘ Verify a motor's position feedback signals.
Motor Marker Diagnostics Verify the operation of the motor marker signal.
Auxiliary Feedback
Diagnostics
Verify the operation of the auxiliary feedback signals.
Auxiliary Motor Marker
Diagnostics
Verify the operation of the motor marker signal.