114 Rockwell Automation Publication 2071-RM001B-EN-P - April 2013
Appendix B Indexing Drive Parameters
Parameter Descriptions
Parameter descriptions list the size of each parameter and the data options within
the parameter.
Descriptions for Standard Drive Parameters begin on page 47
.
Group 0 - Indexing System
[IN00.00] Auto Start Indexing
Ultraware Name Auto Start Indexing
Description When this field is set to ON, the drive begins executing the
selected index whenever the drive enables.
Range Value Description
0OFF
1ON
Default 0
Units N/A
Access Set
Changeable Status Always
When Enabled Power Cycling
Applicable Operating Mode Indexing
Modbus Address 5000
[IN00.01] Abort Index Deceleration
Ultraware Name Abort Index Decel
Description The deceleration used to stop motion when the Stop
Index input terminates an index move.
Range Value Description
1 …2,147,483,647 10
-2
* rev/s
2
for rotary,
mm/s
2
for linear
Default 6250
Access Set
Changeable Status Always
When Enabled Power Cycling
Applicable Operating Mode Indexing
Modbus Address 5001...5002
[IN00.02] Positive Deceleration Distance
Ultraware Name Positive Deceleration Distance
Range Value Description
0 …2,147,483,647 The stopping distance used
when the drive encounters
a positive overtravel limit.
Default 0