Appendix A Standard Drive Parameters
Group 8 - Reserved Parameters
Group 8 parameters are reserved.
[Pr - 7.04] Analog Monitor Output CH1 Scaling
Ultraware Name Calibration: Analog Output CH1 Scale
Range -1000…1000
Default 0
Units -
When Enabled Servo-Off -> Setting -> After power cycle (ENG mode)
Applicable Operating Mode All
[Pr - 7.05] Analog Monitor Output CH2 Offset
Ultraware Name Calibration: Analog Output CH2 Offset
Range -1000…1000
Default 0
Units mV
When Enabled Servo-Off -> Setting -> After power cycle (ENG mode)
Applicable Operating Mode All
[Pr - 7.06] Analog Monitor Output CH2 Scaling
Ultraware Name Calibration: Analog Output CH2 Scale
Range -1000…1000
Default 0
Units -
When Enabled Servo-Off -> Setting -> After power cycle (ENG mode)
Applicable Operating Mode All
[Pr - 7.07] DC Bus Measurement Scaling Calibration
Ultraware Name Calibration: DC Bus ADC Calibration
Description This parameter is a calibration adjustment to the ideal
ADC scaling. The scaling adjustment range is -100% to
+100%, so the ADC scaling can be adjusted from 2* the
ideal scaling to zero.
Range -1000…1000
Default 0 (no adjustment)
Units 0.001
When Enabled Servo-Off -> Setting -> After power cycle (ENG mode)
Applicable Operating Mode All