Rockwell-automation 2098-DSD-xxx Ultra3000 Host Commands for Serial In Uživatelský manuál Strana 98

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 176
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 97
Publication 2098-RM003A-EN-P October 2001
2-82 Command Reference
Motor Rated Voltage
Format: :aa0ECfddddcc<cr>
Parameter
Code:
0x0EC
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields: dddd Rated voltage of the motor, in units of AC RMS
Volts.
Minimum
Value:
100
Maximum
Value:
1000
Default: 230
Zobrazit stránku 97
1 2 ... 93 94 95 96 97 98 99 100 101 102 103 ... 175 176

Komentáře k této Příručce

Žádné komentáře