Rockwell-automation 2098-DSD-xxx Ultra3000 Host Commands for Serial In Uživatelský manuál Strana 66

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 176
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 65
Publication 2098-RM003A-EN-P October 2001
2-50 Command Reference
Index Abort Deceleration
Format: :aa0B9fddddddddcc<cr>
Parameter
Code:
0x0B9
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields: dddddddd Deceleration to be used if the stop index input is
activated, in units of counts/second/second.
Minimum
Value:
0x00000000
Maximum
Value:
0x7FFFFFFF
Default: 100,000