Publication 2098-RM003A-EN-P October 2001
Command Reference 2-3
Power-up Status
Firmware Version
Development Firmware Version
Format: :aa001fddcc<cr>
Parameter
Code:
0x001
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dd Power-up Status, where:
0x00: Successful power-up
0x33-0xFE: Power-up error code as defined in Appendix A.
Format: :aa002fvvrrcc<cr>
Parameter
Code:
0x002
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: vv
rr
Major firmware version.
Minor firmware revision.
Format: :aa179fvvcc<cr>
Parameter
Code:
0x179
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: vv Development firmware version, where a value of 0
indicates a standard release, and anything else
indicates a prototype or beta version.