Ethernet-to-DeviceNet Linking Device 15
Rockwell Automation Publication 1788-IN055C-EN-P - September 2011
The following figure shows a flowchart describing how the IP configuration is
determined when the linking device is powered up.
TIP
You can enable these values using the linking device’s IP Configuration web
page. Refer to Setting the IP Address Using By Using the Web Page on
page 16.
Valid
Conguration
in Flash Memory?
DHCP
Cong
Received?
Valid
Conguration
File?
DIP Switch = 0
DHCP
Enabled?
IP = 192 168.1.n
Sub = 255.255.255.0
No Gateway
Remain oine
Use Valid (stored)
IP address
Request cong
from DHCP/
BOOTP Server.
Timeout 30 secs
Start
Stop
No
Ye s
No
No
No
No
Use received
conguration
Ye s
Ye s
Ye s
Ye s
31445-M