Publication 1792D-IN041B-EN-P - September 2000
Installation Instructions
ArmorBlock MaXum 16 Sinking
Output Module Series B
(Cat. No. 1792D-0VT16E)
This ArmorBlock MaXum I/O module (Cat. No. 1792D-0VT16E) is a
stand-alone 24V dc I/O product which communicates via a
DeviceNet network. The sealed housing of this module requires no
enclosure.
This module has 16 sinking outputs accessed through Y splitter
cables. Outputs are self-protected 24V dc and provide up to 0.3A
each. Local logic control has been added to the Series B version of
this product.
42047
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - Output Module Series B

Publication 1792D-IN041B-EN-P - September 2000Installation InstructionsArmorBlock MaXum 16 Sinking Output Module Series B(Cat. No. 1792D-0VT16E)This A

Strany 2 - Package Contents

10 ArmorBlock MaXum 16 Sinking Output Module Series B Publication 1792D-IN041B-EN-P - September 2000Troubleshoot with the IndicatorsThis module

Strany 3 - Set the Node Address

ArmorBlock MaXum 16 Sinking Output Module Series B 11Publication 1792D-IN041B-EN-P - September 2000The following table describes logic status

Strany 4 - (00-63 PGM)

12 ArmorBlock MaXum 16 Sinking Output Module Series B Publication 1792D-IN041B-EN-P - September 2000Specifications16 Output Module - Cat. No. 1

Strany 5

ArmorBlock MaXum 16 Sinking Output Module Series B 13Publication 1792D-IN041B-EN-P - September 200016 Output Module - Cat. No. 1792D-OVT16EEnc

Strany 6

14 ArmorBlock MaXum 16 Sinking Output Module Series B Publication 1792D-IN041B-EN-P - September 2000Hazardous Location Approval The following i

Strany 7 - DeviceNet Cable

ArmorBlock MaXum 16 Sinking Output Module Series B 15Publication 1792D-IN041B-EN-P - September 2000Les informations suivantes ne concernent qu

Strany 8

Publication 1792D-IN041B-EN-P - September 2000 PN 957395-73Supersedes Publication 1792D-5.41 - August 1999 © 2000 Rockwell International Corporation.

Strany 9

2 ArmorBlock MaXum 16 Sinking Output Module Series B Publication 1792D-IN041B-EN-P - September 2000Package ContentsYour package contains:• 1 Ar

Strany 10

ArmorBlock MaXum 16 Sinking Output Module Series B 3Publication 1792D-IN041B-EN-P - September 2000Install Your ArmorBlock MaXum I/O ModuleTo i

Strany 11

4 ArmorBlock MaXum 16 Sinking Output Module Series B Publication 1792D-IN041B-EN-P - September 2000Refer to the illustration of the node addres

Strany 12 - Specifications

ArmorBlock MaXum 16 Sinking Output Module Series B 5Publication 1792D-IN041B-EN-P - September 20001. Position the module over the mounted cabl

Strany 13

6 ArmorBlock MaXum 16 Sinking Output Module Series B Publication 1792D-IN041B-EN-P - September 2000Connect the Output Cord Sets to the MaXum Mo

Strany 14 - Hazardous Location Approval

ArmorBlock MaXum 16 Sinking Output Module Series B 7Publication 1792D-IN041B-EN-P - September 2000I/O connectors for this module are shown bel

Strany 15 - AVERTISSEMENT

8 ArmorBlock MaXum 16 Sinking Output Module Series B Publication 1792D-IN041B-EN-P - September 2000Communicate with Your ArmorBlock MaXum I/O M

Strany 16

ArmorBlock MaXum 16 Sinking Output Module Series B 9Publication 1792D-IN041B-EN-P - September 2000The DeviceNet Network uses advanced network