Ethernet-to-DeviceNet Linking Device 13
Rockwell Automation Publication 1788-IN055C-EN-P - September 2011
The switch represents the binary value of the last byte in the 4-byte IP address. In
this case it is n. If n = 0, the linking device obtains its IP address from the
software configuration (DHCP or web page).
Setting the IP Address By Using DHCP/BootP
When DHCP/BootP is enabled and a DHCP or BootP server is found, the
IP address, Subnet mask, and Gateway address are automatically configured
by the DHCP server, as shown in the following figure.
Automatic Configuration
Follow these steps to change the IP address, Subnet mask, and Gateway address
from this dialog box.
IP address 192.168.1.n
Subnet mask 255.255.255.0
Gateway address 0.0.0.0 (No gateway set)
TIP
The use of DHCP is the default configuration for the linking device as shipped.
The IP address configuration DIP switch ships with n =0.