Publication 1760-UM002B-EN-P - March 2005
3-14 Commissioning
Configuring a Pico-Link
Network
If you want to work with the Pico-Link network and communicate with several
stations, the network must be configured first.
Proceed as follows:
1. Connect all network stations. Pico-Link socket 2e to Pico-Link socket
1L.
2. The first station 1 (socket 1L) and the last station (socket 2e) must be
provided with a network termination resistor a.
3. Connect all stations to the power supply.
Figure 3.10 Example topology with two Pico-Link stations
1. Switch on the power supply on all stations.
2. Ensure that all stations have a power supply. The POW LED must light
up or flash. It is only possible to configure the stations which are
supplied with voltage.
R1 – 12
S1 – S8
Terminating
Resistor
Resistor
Location 1
Station 1
Location 2
Station 2
GFX-70
1
1