System Commissioning Chapter 6
1. Click Copy from Design
to Runtime.
This RSLinx Enterprise
dialog box opens.
2. Click Yes.
3. Click Verify to make sure communication is setup
correctly.
The Shortcut Verifier dialog box opens.
4. Verify that the path to the Design device
and the Runtime device are assigned.
5. Click Close.
6. Click OK to save the configuration.
Create Your FactoryTalk View Runtime Application File
In this example you create a runtime file for downloading to a PanelView Plus terminal.
1. From the Application menu, choose Create Runtime
Application.
The Create Runtime Application dialog box opens.