36 FLEX Ex 8 Output and HART Analog Modules
Publication
1797-5.3 - September 2011
Weight 200 g (approximately)
Keyswitch Position 4
Environmental Conditions
Operational Temperature
-20…+70
o
C (-4…+158
o
F)
Storage Temperature
-40…+85
o
C (-40…+185
o
F)
Relative Humidity 5…95% noncondensing
Shock Operating Tested to 15 g peak acceleration, 11(+1) ms pulse width
Nonoperating Tested to 15 g peak acceleration, 11(+1) ms pulse width
Vibration Tested 2 g @ 10…500 Hz per IEC68-2-6
Agency Certification
CENELEC II (1) 2G Ex ib[ia] IIC T4
II (1) D [Ex iaD]
UL, C-UL Class I, Groups A, B, C and D; Class II, Groups E, F and G;
Class III Hazardous Locations
Class I, Zone 1, AEx ib[ia] IIC T4
FM Intrinsically safe Class I, Div 1, Groups A, B, C, D, T4.
Associated Apparatus with intrinsically safe Connections
Class I, II, III, Div 1, Groups A--G
Intrinsically safe Class I, Zone 1, AEx ib[ia] IIC T4.
IECEx [Zone 0] Ex ib[ia] IIC T4
[Ex iaD]
INMETRO BR-Ex ia/ib IIB/IIC T4