Rockwell-automation 1797-OE8H FLEX Ex 8 Output Analog Modules Uživatelský manuál Strana 34

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 52
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 33
34 FLEX Ex 8 Output and HART Analog Modules
Publication
1797-5.3 - September 2011
Repair
Status Indicators
Specifications
ATTENTION
This module is not field repairable. Any attempt to open the module will void the
warranty and IS certification. If repair is necessary, return the module to the
factory.
Interpret the Status Indicators
Status Description
Flashing red Channel fault -
Channel 0 indicator will turn red while power-up check is running
Solid green Power applied to module
Specifications - 1797-OE8
Number of Outputs 8 single-ended, nonisolated
IS input type Ex ia IIB/IIC T4
AEx ia IIC T4
Class I, II, III Division 1 Group A-G T4
45096
Input Status
Power Status
Zobrazit stránku 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 51 52

Komentáře k této Příručce

Žádné komentáře