Publication 1784-UM003A-EN-P – June 2003
Configuring a Kinetix 6000 Drive 233
Module Info Tab
The Module Info Tab displays module and status information about the
module. It also allows you to reset a module to its power-up state. The
information on this tab is not displayed if you are either offline or currently
creating a module
Figure 10.10 Module Properties - Module Info
The data on this tab comes directly from the module. If you selected a
Listen-Only communication format when you created the module, this tab is
not available.
Refresh to display new data from the module.
Reset Module to return the module to its power-up state by emulating
the cycling of power. By doing this, you also clear all faults.
TIP
You can use this tab to determine the identity of the
module.