Shrnutí obsahu

Strany 1 - SoftLogix

SoftLogixTM Motion Card (Cat.No. 1784-PM02AE, -PM16SE)Setup and Configuration Manual

Strany 2 - Important User Information

Publication 1784-UM003A-EN-P – June 20032 Using This ManualRelated DocumentationThe following table lists related ControlLogix documentation:Fo

Strany 3 - Directive Compliance

Publication 1784-UM003A-EN-P – June 200392 Naming & Configuring Your Motion AxisIn the Controller Organizer, right click on the axis to edi

Strany 4

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 93The General screen shown below is for an AXIS_SERVO DRIVE D

Strany 5 - Table of Contents

Publication 1784-UM003A-EN-P – June 200394 Naming & Configuring Your Motion AxisGeneral Tab – AXIS_SERVOUse this tab to do the following fo

Strany 6 - ii

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 95New Group buttonOpens the New Tag dialog box, where you can

Strany 7 - Chapter 13

Publication 1784-UM003A-EN-P – June 200396 Naming & Configuring Your Motion AxisAxis ConfigurationSelects and displays the intended use of

Strany 8 - iv

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 97General Tab - AXIS_VIRTUALUse this tab to associate the axi

Strany 9 - Using This Manual

Publication 1784-UM003A-EN-P – June 200398 Naming & Configuring Your Motion AxisPress Apply then select the Motion Planner tab to access th

Strany 10 - Rockwell Automation

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 99Program Stop ActionSelect how a specific axis is stopped wh

Strany 11 - On the Web

Publication 1784-UM003A-EN-P – June 2003100 Naming & Configuring Your Motion AxisEnable Master Position Filter CheckboxUse this checkbox to

Strany 12 - 4 Using This Manual

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 101Units TabThe Units Tab is the same for all axis data types

Strany 13 - SoftLogix Motion Control

Publication 1784-UM003A-EN-P – June 2003Using This Manual 3Local Product SupportContact your local Rockwell Automation representative for:• sal

Strany 14 - SoftLogix Motion System

Publication 1784-UM003A-EN-P – June 2003102 Naming & Configuring Your Motion AxisServo Tab - AXIS_SERVOClick on the Servo Tab from the Axis

Strany 15 - SoftLogix Chassis Monitor

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 103External Drive ConfigurationSelect the drive type for the

Strany 16 - The SoftLogix Controller

Publication 1784-UM003A-EN-P – June 2003104 Naming & Configuring Your Motion AxisFeedback Tab – (AXIS_SERVO)The Feedback Tab allows you to

Strany 17 - Module (1784-PM16SE)

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 105Drive/Motor Tab -(AXIS_SERVO_DRIVE)Use this tab to configu

Strany 18 - Control Application

Publication 1784-UM003A-EN-P – June 2003106 Naming & Configuring Your Motion AxisCatalog NumberSelect the catalog number of the motor assoc

Strany 19 - Parameters

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 107Drive ResolutionType in the number of counts per motor rev

Strany 20 - Minor/Major Faults

Publication 1784-UM003A-EN-P – June 2003108 Naming & Configuring Your Motion AxisFigure 6.14 Change Catalog ScreenCatalog NumberLists the a

Strany 21 - SoftLogix Controller

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 109Motor Feedback Tab -AXIS_SERVO_DRIVEUse this tab to config

Strany 22 - Controller Dialog

Publication 1784-UM003A-EN-P – June 2003110 Naming & Configuring Your Motion AxisPerThe units used to measure the cycles.Interpolation Fact

Strany 23 - Redundancy Enabled

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 111CyclesThe number of cycles of the auxiliary feedback devic

Strany 24 - Create In:

Publication 1784-UM003A-EN-P – June 20034 Using This Manual

Strany 25 - Editing Controller

Publication 1784-UM003A-EN-P – June 2003112 Naming & Configuring Your Motion AxisThe differences in the appearance of the Conversion Tab sc

Strany 26

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 113Positioning ModeThis parameter is not editable for an axis

Strany 27 - Overview

Publication 1784-UM003A-EN-P – June 2003114 Naming & Configuring Your Motion AxisFor axes of the type AXIS_SERVO_DRIVE:• when you save an e

Strany 28 - Data Bits

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 115ModeSelect the homing mode:• Active: In this mode, the des

Strany 29 - RTS Off Delay

Publication 1784-UM003A-EN-P – June 2003116 Naming & Configuring Your Motion AxisSequenceSelect the event that causes the Home Position to

Strany 30 - Station Address

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 117SpeedType the speed of the jog profile used in the first l

Strany 31 - DF1 Point to Point Parameters

Publication 1784-UM003A-EN-P – June 2003118 Naming & Configuring Your Motion Axis Homing Tab - AXIS_VIRTUALUse this tab to configure the at

Strany 32 - DF1 Master Parameters

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 119If the Positioning Mode (set in the Conversion tab) of the

Strany 33 - DH485 Parameters

Publication 1784-UM003A-EN-P – June 2003120 Naming & Configuring Your Motion AxisFeedback PolarityThe polarity of the encoder feedback, thi

Strany 34 - Buffer Size

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 121Test FeedbackRuns the Feedback Test, which checks and, if

Strany 35 - Echo Mode

5 Publication 1784-UM003A-EN-P – June 2003Chapter 1The SoftLogix Motion Control SystemThis chapter describes the SoftLogix motion control system and i

Strany 36 - Major Faults Tab

Publication 1784-UM003A-EN-P – June 2003122 Naming & Configuring Your Motion AxisTest IncrementSpecifies the amount of distance traversed b

Strany 37 - Minor Faults Tab

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 123Test Command & FeedbackRuns the Command & Feedback

Strany 38 - Date/Time Tab

Publication 1784-UM003A-EN-P – June 2003124 Naming & Configuring Your Motion AxisSpeedDetermines the maximum speed for the tune process. Th

Strany 39

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 125TuneSelect the gains to be determined by the tuning test:•

Strany 40 - Memory Total

Publication 1784-UM003A-EN-P – June 2003126 Naming & Configuring Your Motion AxisDynamics TabUse this tab to view or edit the dynamics rela

Strany 41 - SFC Execution Tab

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 127Maximum VelocityThe steady-state speed of the axis, it is

Strany 42 - Last Scan of Active Steps

Publication 1784-UM003A-EN-P – June 2003128 Naming & Configuring Your Motion AxisManual AdjustClick on this button to open the Dynamics tab

Strany 43 - File Tab

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 129Gains Tab - AXIS_SERVOUse this tab to perform the followin

Strany 44 - Redundancy Status

Publication 1784-UM003A-EN-P – June 2003130 Naming & Configuring Your Motion AxisNote: The parameters on this tab become read-only and cann

Strany 45

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 131Proportional (Position) GainPosition Error is multiplied b

Strany 46 - Partner Minor Faults

Publication 1784-UM003A-EN-P – June 20036 The SoftLogix Motion Control SystemFigure 1.1 SoftLogix System with 1784-PM02AEFigure 1.2 SoftLogix S

Strany 47 - Nonvolatile Memory Tab

Publication 1784-UM003A-EN-P – June 2003132 Naming & Configuring Your Motion AxisWhile the Pos I Gain, if employed, is typically establishe

Strany 48

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 133Due to the destabilizing nature of Integral Gain, it is re

Strany 49

Publication 1784-UM003A-EN-P – June 2003134 Naming & Configuring Your Motion AxisGains Tab - AXIS_SERVO_DRIVEUse this tab to perform the fo

Strany 50 - Image Note

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 135The parameters on this tab can be edited in either of two

Strany 51 - Load/Store

Publication 1784-UM003A-EN-P – June 2003136 Naming & Configuring Your Motion AxisNote: Acceleration Feedforward Gain is not applicable for

Strany 52

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 137Output tab of this dialog box). Once this is done, the Pos

Strany 53 - Motion Module

Publication 1784-UM003A-EN-P – June 2003138 Naming & Configuring Your Motion AxisDue to the destabilizing nature of Integral Gain, it is re

Strany 54

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 139Manual AdjustClick on this button to access the Gains tab

Strany 55 - New Module

Publication 1784-UM003A-EN-P – June 2003140 Naming & Configuring Your Motion AxisSet Custom GainsClick on this button to open the Custom Ga

Strany 56

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 141Output Tab - AXIS_SERVOUse this dialog for offline configu

Strany 57

Publication 1784-UM003A-EN-P – June 2003The SoftLogix Motion Control System 7SoftLogix Chassis MonitorIt is at the Chassis Monitor where you ca

Strany 58

Publication 1784-UM003A-EN-P – June 2003142 Naming & Configuring Your Motion AxisVelocity ScalingThe Velocity Scaling attribute is used to

Strany 59 - Settings

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 143Enable Low-pass Output Filter Select this to enable the se

Strany 60

Publication 1784-UM003A-EN-P – June 2003144 Naming & Configuring Your Motion AxisManual AdjustClick on this button to access the Output tab

Strany 61

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 145Output Tab (AXIS_SERVO_DRIVE)Use this dialog box to make t

Strany 62

Publication 1784-UM003A-EN-P – June 2003146 Naming & Configuring Your Motion AxisTorque ScalingThe Torque Scaling attribute is used to conv

Strany 63 - Inhibit Module checkbox

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 147Note: During tuning, if the controller detects a high degr

Strany 64 - Associated Axes Tab

Publication 1784-UM003A-EN-P – June 2003148 Naming & Configuring Your Motion AxisNote: The Manual Adjust button is disabled when RSLogix 50

Strany 65 - Channel 1

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 149Note: The parameters on this tab become read-only and cann

Strany 66

Publication 1784-UM003A-EN-P – June 2003150 Naming & Configuring Your Motion AxisNote: This value is set to twice the following error at ma

Strany 67

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 151Manual AdjustClick on this button to open the Limits tab o

Strany 68 - Motion Modules

Publication 1784-UM003A-EN-P – June 20038 The SoftLogix Motion Control SystemAdditional information in the form of a tooltip about the modules

Strany 69 - Adding the 1784-PM16SE

Publication 1784-UM003A-EN-P – June 2003152 Naming & Configuring Your Motion Axis Limits Tab - AXIS_SERVO_DRIVEUse this tab to make the fol

Strany 70 - 4. Select 1784-PM16SE

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 153Hard Travel LimitsEnables a periodic test that monitors th

Strany 71

Publication 1784-UM003A-EN-P – June 2003154 Naming & Configuring Your Motion AxisNote: This value is set to twice the following error at ma

Strany 72

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 155Set Custom LimitsClick this button to open the Custom Limi

Strany 73

Publication 1784-UM003A-EN-P – June 2003156 Naming & Configuring Your Motion AxisVelocityLimitPositive This attribute displays the maximum

Strany 74 - Card Overview

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 157Offset Tab - AXIS_SERVOUse this tab to make offline adjust

Strany 75 - Editing 1784-PM16SE Card

Publication 1784-UM003A-EN-P – June 2003158 Naming & Configuring Your Motion AxisWhen RSLogix 5000 is offline, the following parameters can

Strany 76

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 159Output OffsetCorrects the problem of axis “drift”, by addi

Strany 77

Publication 1784-UM003A-EN-P – June 2003160 Naming & Configuring Your Motion AxisOffset Tab - AXIS_SERVO_DRIVEUse this tab to make offline

Strany 78

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 161When RSLogix 5000 is offline, the following parameters can

Strany 79

Publication 1784-UM003A-EN-P – June 2003The SoftLogix Motion Control System 9The Analog/Encoder Servo Module(1784-PMO2AE)The Analog/Encoder ser

Strany 80 - SERCOS Interface Tab

Publication 1784-UM003A-EN-P – June 2003162 Naming & Configuring Your Motion AxisManual AdjustClick on this button to open the Offset tab o

Strany 81 - Cycle Time

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 163Fault Actions Tab - AXIS_SERVOUse this tab to specify the

Strany 82 - Ring Comm. Phase

Publication 1784-UM003A-EN-P – June 2003164 Naming & Configuring Your Motion AxisSelect one of the following fault actions for each fault t

Strany 83 - Fault Type

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 165Feedback LossSpecifies the fault action to be taken when f

Strany 84

Publication 1784-UM003A-EN-P – June 2003166 Naming & Configuring Your Motion AxisFault Actions Tab -AXIS_SERVO_DRIVEUse this tab to specify

Strany 85

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 167Select one of the following fault actions for each fault t

Strany 86

Publication 1784-UM003A-EN-P – June 2003168 Naming & Configuring Your Motion AxisMotor ThermalSpecifies the fault action to be taken when a

Strany 87 - The Motion Group

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 169Set Custom Stop ActionOpens the Custom Stop Action Attribu

Strany 88 - 80 The Motion Group

Publication 1784-UM003A-EN-P – June 2003170 Naming & Configuring Your Motion AxisTag TabUse this tab to modify the name and description of

Strany 89 - The Motion Group 81

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 171Tag TypeIndicates the type of the current tag. This type m

Strany 90 - Editing the Motion Group

Publication 1784-UM003A-EN-P – June 200310 The SoftLogix Motion Control SystemDeveloping a Motion Control Application ProgramThis section provi

Strany 91 - The Motion Group 83

Publication 1784-UM003A-EN-P – June 2003172 Naming & Configuring Your Motion Axis

Strany 92 - Reset Max

173 Publication 1784-UM003A-EN-P – June 2003Chapter 7Creating & Configuring Your Coordinate System TagIntroductionThe Coordinate System tag is use

Strany 93 - Tag Type (read-only)

Publication 1784-UM003A-EN-P – June 2003174 Creating & Configuring Your Coordinate System TagThe second way is to go the Controller organiz

Strany 94 - Base Tag

Publication 1784-UM003A-EN-P – June 2003Creating & Configuring Your Coordinate System Tag 175Regardless of the method you use the New Tag w

Strany 95 - Naming an Axis

Publication 1784-UM003A-EN-P – June 2003176 Creating & Configuring Your Coordinate System TagMake entries in the following fields.NameEnter

Strany 96

Publication 1784-UM003A-EN-P – June 2003Creating & Configuring Your Coordinate System Tag 177Data TypeIn the Data Type field select COORDIN

Strany 97

Publication 1784-UM003A-EN-P – June 2003178 Creating & Configuring Your Coordinate System Tag General Wizard ScreenThe General screen lets

Strany 98

Publication 1784-UM003A-EN-P – June 2003Creating & Configuring Your Coordinate System Tag 179Editing Coordinate System PropertiesOnce you h

Strany 99 - Editing Motion Axis

Publication 1784-UM003A-EN-P – June 2003180 Creating & Configuring Your Coordinate System TagGeneral TabUse this tab to do the following fo

Strany 100

Publication 1784-UM003A-EN-P – June 2003Creating & Configuring Your Coordinate System Tag 181Axis GridThe Axis Grid is where you associate

Strany 101

Publication 1784-UM003A-EN-P – June 2003The SoftLogix Motion Control System 11 For more information about the MOTION_INSTRUCTION tag, refer t

Strany 102 - Ellipsis (…) button

Publication 1784-UM003A-EN-P – June 2003182 Creating & Configuring Your Coordinate System TagEnable Coordinate System Auto Tag UpdateThe En

Strany 103 - Module Type

Publication 1784-UM003A-EN-P – June 2003Creating & Configuring Your Coordinate System Tag 183Units TabThe Units Tab of the Coordinate Syste

Strany 104

Publication 1784-UM003A-EN-P – June 2003184 Creating & Configuring Your Coordinate System TagClick on the Apply button to preserve your edi

Strany 105 - General Tab - AXIS_VIRTUAL

Publication 1784-UM003A-EN-P – June 2003Creating & Configuring Your Coordinate System Tag 185Maximum SpeedEnter the value for Maximum Speed

Strany 106 - Output Cam Execution Targets

Publication 1784-UM003A-EN-P – June 2003186 Creating & Configuring Your Coordinate System TagDynamics Tab Manual AdjustAt this screen you c

Strany 107 - Program Stop Action

Publication 1784-UM003A-EN-P – June 2003Creating & Configuring Your Coordinate System Tag 187Tag TabThe Tag Tab is for reviewing your Tag i

Strany 108

Publication 1784-UM003A-EN-P – June 2003188 Creating & Configuring Your Coordinate System TagTag TypeIndicates the type of the current Coor

Strany 109 - Average Velocity Timebase

Publication 1784-UM003A-EN-P – June 2003Creating & Configuring Your Coordinate System Tag 189The menu has the following options:• Monitor C

Strany 110 - Servo Tab - AXIS_SERVO

Publication 1784-UM003A-EN-P – June 2003190 Creating & Configuring Your Coordinate System TagCut/PasteA Cut/Paste operation is used for mov

Strany 111

191 Publication 1784-UM003A-EN-P – June 2003Chapter 8Configuring a 1394x-SJTxx-D Digital Servo DriveTo configure a 1394x-SJTxx-D drive module:1. In th

Strany 112 - Feedback Type

Important User InformationBecause of the variety of uses for the products described in this publication, those responsible for the application and use

Strany 113 - Amplifier Catalog Number

Publication 1784-UM003A-EN-P – June 200312 The SoftLogix Motion Control SystemHandling Motion FaultsTwo types of motion faults exist.ErrorsExec

Strany 114 - Loop Configuration

Publication 1784-UM003A-EN-P – June 2003192 Configuring a 1394x-SJTxx-D Digital Servo Drive3. You can also right click on a selected 1784-PM16S

Strany 115 - Change Catalog…button

Publication 1784-UM003A-EN-P – June 2003Configuring a 1394x-SJTxx-D Digital Servo Drive 1936. Fill in the required parameters for each page, th

Strany 116

Publication 1784-UM003A-EN-P – June 2003194 Configuring a 1394x-SJTxx-D Digital Servo DriveThe module for a 1394x-SJTxx-D drive has 5 tabs: Fig

Strany 117 - Feedback Type

Publication 1784-UM003A-EN-P – June 2003Configuring a 1394x-SJTxx-D Digital Servo Drive 195 On this tab, you can:• view the type and descriptio

Strany 118 - Aux Feedback Tab

Publication 1784-UM003A-EN-P – June 2003196 Configuring a 1394x-SJTxx-D Digital Servo DriveThe major revision is used to indicate the revision

Strany 119 - Feedback Ratio

Publication 1784-UM003A-EN-P – June 2003Configuring a 1394x-SJTxx-D Digital Servo Drive 197This feature prevents the inadvertent insertion of t

Strany 120 - Conversion Tab

Publication 1784-UM003A-EN-P – June 2003198 Configuring a 1394x-SJTxx-D Digital Servo DriveInhibit Module CheckboxCheck/Uncheck this box to inh

Strany 121 - Position Unwind

Publication 1784-UM003A-EN-P – June 2003Configuring a 1394x-SJTxx-D Digital Servo Drive 199Module FaultDisplays the fault code returned from th

Strany 122 - Homing Tab - AXIS_SERVO and

Publication 1784-UM003A-EN-P – June 2003200 Configuring a 1394x-SJTxx-D Digital Servo DriveNode X0Represents Axis 0 on the 1784-PM16SE SERCOS m

Strany 123 - Position

Publication 1784-UM003A-EN-P – June 2003Configuring a 1394x-SJTxx-D Digital Servo Drive 201 Power TabUse this tab to select a bus regulator for

Strany 124 - Direction

13 Publication 1784-UM003A-EN-P – June 2003Chapter 2SoftLogix ControllerIntroductionBefore you can begin programming or configuring your controller, y

Strany 125 - Homing Configurations

Publication 1784-UM003A-EN-P – June 2003202 Configuring a 1394x-SJTxx-D Digital Servo DriveModule Info tabUse this tab to display identifying a

Strany 126 - Homing Tab - AXIS_VIRTUAL

Publication 1784-UM003A-EN-P – June 2003Configuring a 1394x-SJTxx-D Digital Servo Drive 203Product NameThe name displayed in the Product Name f

Strany 127 - Test Increment

Publication 1784-UM003A-EN-P – June 2003204 Configuring a 1394x-SJTxx-D Digital Servo DriveModule IdentityThis field does not take into account

Strany 128 - Test Marker

205 Publication 1784-UM003A-EN-P – June 2003Chapter 9Configuring an Ultra 3000 DriveThe Ultra3000 Digital Servo Drive with fiber optic SERCOS interfac

Strany 129 - Test Output & Feedback

Publication 1784-UM003A-EN-P – June 2003206 Configuring an Ultra 3000 Drive4. Select New Module from the pop up menu.Figure 9.2 New Module Sele

Strany 130 - Test Marker

Publication 1784-UM003A-EN-P – June 2003Configuring an Ultra 3000 Drive 207The Select Module Type dialog displays.Figure 9.3 Select Module Type

Strany 131 - Travel Limit

Publication 1784-UM003A-EN-P – June 2003208 Configuring an Ultra 3000 Drive6. Press the OK button to close the Select Module Type dialog. The U

Strany 132 - Damping Factor

Publication 1784-UM003A-EN-P – June 2003Configuring an Ultra 3000 Drive 2098. Fill in the required information and click on the Next button to

Strany 133 - Start Tuning

Publication 1784-UM003A-EN-P – June 2003210 Configuring an Ultra 3000 Drive10. There is no Bus regulator for the Ultra3000. Press Next to conti

Strany 134 - Dynamics Tab

Publication 1784-UM003A-EN-P – June 2003Configuring an Ultra 3000 Drive 211Editing the Ultra Drive PropertiesThe Module Properties for any of t

Strany 135 - Maximum Deceleration

Publication 1784-UM003A-EN-P – June 200314 SoftLogix ControllerIn addition, if you have chosen a FlexLogix controller, 2 FlexBus adapters are c

Strany 136 - Manual Adjust

Publication 1784-UM003A-EN-P – June 2003212 Configuring an Ultra 3000 DriveVendorDisplays the vendor of the module being created (read only).Na

Strany 137 - Gains Tab - AXIS_SERVO

Publication 1784-UM003A-EN-P – June 2003Configuring an Ultra 3000 Drive 213Electronic Keying Select one of these keying options for your module

Strany 138 - Acceleration Feedforward

Publication 1784-UM003A-EN-P – June 2003214 Configuring an Ultra 3000 DriveStatusDisplays the status the controller has about the module:Connec

Strany 139 - Integral (Position) Gain

Publication 1784-UM003A-EN-P – June 2003Configuring an Ultra 3000 Drive 215On this tab, you can: • Select a requested packet interval.• Choose

Strany 140 - Integral (Velocity) Gain

Publication 1784-UM003A-EN-P – June 2003216 Configuring an Ultra 3000 DriveWhen you check this box and go online, the icon representing this mo

Strany 141 - Integrator Hold

Publication 1784-UM003A-EN-P – June 2003Configuring an Ultra 3000 Drive 217Associated Axes Tab (Ultra3000Drives)Use this tab to configure the s

Strany 142 - Gains Tab - AXIS_SERVO_DRIVE

Publication 1784-UM003A-EN-P – June 2003218 Configuring an Ultra 3000 DrivePower Tab - Ultra DriveUse this tab to select a bus regulator for yo

Strany 143

Publication 1784-UM003A-EN-P – June 2003Configuring an Ultra 3000 Drive 219Module Info TabThe Module Info Tab displays module and status inform

Strany 144

Publication 1784-UM003A-EN-P – June 2003220 Configuring an Ultra 3000 DriveIdentificationDisplays the module’s:• Vendor• Product Type• Product

Strany 145

Publication 1784-UM003A-EN-P – June 2003Configuring an Ultra 3000 Drive 221ConfiguredDisplays a yes or no value indicating whether the module h

Strany 146

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 15VendorDisplays the name of the controller’s manufacturer.TypeSelect the controll

Strany 147

Publication 1784-UM003A-EN-P – June 2003222 Configuring an Ultra 3000 DriveReset ModuleClick on this button to return a module to its power-up

Strany 148 - Attribute

223 Publication 1784-UM003A-EN-P – June 2003Chapter 10Configuring a Kinetix 6000 DriveThe Kinetix 6000 Digital Servo Drive with fiber optic SERCOS int

Strany 149 - Output Tab - AXIS_SERVO

Publication 1784-UM003A-EN-P – June 2003224 Configuring a Kinetix 6000 Drive2. Select New Module from the pop up menu.Figure 10.2 New Module Se

Strany 150 - Torque Scaling

Publication 1784-UM003A-EN-P – June 2003Configuring a Kinetix 6000 Drive 2254. Press the OK button to close the Select Module Type dialog. The

Strany 151

Publication 1784-UM003A-EN-P – June 2003226 Configuring a Kinetix 6000 DriveThe Module Properties screen displays.Figure 10.6 Module Properties

Strany 152

Publication 1784-UM003A-EN-P – June 2003Configuring a Kinetix 6000 Drive 227DescriptionEnter a description for the module here, up to 128 chara

Strany 153 - Output Tab (AXIS_SERVO_DRIVE)

Publication 1784-UM003A-EN-P – June 2003228 Configuring a Kinetix 6000 DriveStatusDisplays the status the controller has about the module:ATTEN

Strany 154 - Enable Low-pass Output Filter

Publication 1784-UM003A-EN-P – June 2003Configuring a Kinetix 6000 Drive 229Connection TabUse this tab to define controller to module behavior.

Strany 155

Publication 1784-UM003A-EN-P – June 2003230 Configuring a Kinetix 6000 DriveInhibit ModuleCheck/Uncheck this box to inhibit/uninhibit your conn

Strany 156 - Limits Tab - AXIS_SERVO

Publication 1784-UM003A-EN-P – June 2003Configuring a Kinetix 6000 Drive 231Module FaultDisplays the fault code returned from the controller (r

Strany 157 - Position Error Tolerance

Publication 1784-UM003A-EN-P – June 200316 SoftLogix ControllerChassis TypeSelect the appropriate chassis type from the pull-down menu, shown h

Strany 158 - Output Limit

Publication 1784-UM003A-EN-P – June 2003232 Configuring a Kinetix 6000 DriveNodeDisplays the selected node of the Kinetix 6000 drive, as entere

Strany 159

Publication 1784-UM003A-EN-P – June 2003Configuring a Kinetix 6000 Drive 233Module Info TabThe Module Info Tab displays module and status infor

Strany 160

Publication 1784-UM003A-EN-P – June 2003234 Configuring a Kinetix 6000 DriveIdentificationDisplays the module’s:• Vendor• Product Type• Product

Strany 161 - Hard Travel Limits

Publication 1784-UM003A-EN-P – June 2003Configuring a Kinetix 6000 Drive 235ConfiguredDisplays a yes or no value indicating whether the module

Strany 162

Publication 1784-UM003A-EN-P – June 2003236 Configuring a Kinetix 6000 DriveRefreshClick on this button to refresh the tab with new data from t

Strany 163 - Set Custom Limits

237 Publication 1784-UM003A-EN-P – June 2003Chapter 11Configuring an 8720MC DriveThe Allen-Bradley 8720MC Drive System is a family of products designe

Strany 164

Publication 1784-UM003A-EN-P – June 2003238 Configuring an 8720MC DriveOR1. Right click on the selected or 1784-PM16SE module in the I/O Config

Strany 165 - Offset Tab - AXIS_SERVO

Publication 1784-UM003A-EN-P – June 2003Configuring an 8720MC Drive 2393. In the Select Module Type dialog, select the desired drive module. Th

Strany 166 - Torque Offset

Publication 1784-UM003A-EN-P – June 2003240 Configuring an 8720MC DriveEditing the 8720MC Drive PropertiesThe Module Properties for any of the

Strany 167 - Output Offset

Publication 1784-UM003A-EN-P – June 2003Configuring an 8720MC Drive 241TypeDisplays the type and description of the module being created (read

Strany 168 - Offset Tab - AXIS_SERVO_DRIVE

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 17Editing Controller PropertiesThe Controller Properties dialog displays controlle

Strany 169

Publication 1784-UM003A-EN-P – June 2003242 Configuring an 8720MC DriveElectronic Keying Select one of these keying options for your module dur

Strany 170

Publication 1784-UM003A-EN-P – June 2003Configuring an 8720MC Drive 243StatusDisplays the status the controller has about the module:Connection

Strany 171

Publication 1784-UM003A-EN-P – June 2003244 Configuring an 8720MC DriveOn this tab, you can: • Select a requested packet interval.• Choose to i

Strany 172 - Feedback Noise

Publication 1784-UM003A-EN-P – June 2003Configuring an 8720MC Drive 245 Major Fault on Controller if Connection Fails checkboxCheck this box to

Strany 173 - Soft Overtravel

Publication 1784-UM003A-EN-P – June 2003246 Configuring an 8720MC DriveAssociated Axes Tab (8720MCDrives)Use this tab to configure the selected

Strany 174 - Fault Actions Tab

Publication 1784-UM003A-EN-P – June 2003Configuring an 8720MC Drive 247Power Tab - 8720MC DriveUse this tab to select a bus regulator for your

Strany 175 - Drive Thermal

Publication 1784-UM003A-EN-P – June 2003248 Configuring an 8720MC DriveModule Info TabThe Module Info Tab displays module and status informatio

Strany 176

Publication 1784-UM003A-EN-P – June 2003Configuring an 8720MC Drive 249IdentificationDisplays the module’s:• Vendor• Product Type• Product Code

Strany 177 - Set Custom Stop Action

Publication 1784-UM003A-EN-P – June 2003250 Configuring an 8720MC DriveConfiguredDisplays a yes or no value indicating whether the module has b

Strany 178 - Description

Publication 1784-UM003A-EN-P – June 2003Configuring an 8720MC Drive 251RefreshClick on this button to refresh the tab with new data from the mo

Strany 179 - Motion Axes

Publication 1784-UM003A-EN-P – June 200318 SoftLogix ControllerNameThe name of the controller. When you create a project, this is the same as t

Strany 180

Publication 1784-UM003A-EN-P – June 2003252 Configuring an 8720MC Drive

Strany 181 - System Tag

253 Publication 1784-UM003A-EN-P – June 2003Chapter 12Motion InstructionsThis chapter describes the motion instructions for RSLogix 5000 programming s

Strany 182

Publication 1784-UM003A-EN-P – June 2003254 Motion InstructionsFor more information about motion state instructions, refer to the Motion State

Strany 183 - New Tag Parameters

Publication 1784-UM003A-EN-P – June 2003Motion Instructions 255Motion Group InstructionsMotion group instructions initiate action on all axes i

Strany 184 - Alias For:

Publication 1784-UM003A-EN-P – June 2003256 Motion InstructionsThe motion configuration instructions are:For more information about motion stat

Strany 185 - Data Type

Publication 1784-UM003A-EN-P – June 2003Motion Instructions 257Motion Direct CommandsThe Motion Direct Commands feature lets you issue motion c

Strany 186 - Tag Wizard Screen

Publication 1784-UM003A-EN-P – June 2003258 Motion InstructionsWhen you access the Motion Direct Commands dialog from the Tools pull-down, it d

Strany 187 - Properties

Publication 1784-UM003A-EN-P – June 2003Motion Instructions 259From Group in the ControllerOrganizerYou can access the Motion Direct Commands b

Strany 188

Publication 1784-UM003A-EN-P – June 2003260 Motion InstructionsWhen the Motion Direct Commands dialog is accessed from the Motion Group in the

Strany 189 - Axis Grid

Publication 1784-UM003A-EN-P – June 2003Motion Instructions 261From Axis in the Controller OrganizerYou can access the Motion Direct Commands b

Strany 190

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 19Change Controller Type Dialog BoxOverviewUse this dialog to change your controll

Strany 191 - Coordination Units

Publication 1784-UM003A-EN-P – June 2003262 Motion InstructionsWhen the Motion Direct Commands dialog is accessed from an Axis in the Controlle

Strany 192 - Vector Box

Publication 1784-UM003A-EN-P – June 2003Motion Instructions 263Motion MoveMotion GroupMotion EventFor more information about the use and operat

Strany 193 - Position Tolerance Box

Publication 1784-UM003A-EN-P – June 2003264 Motion InstructionsMotion Direct Command DialogThe Motion Direct Commands dialog is similar in posi

Strany 194 - Reset Button

Publication 1784-UM003A-EN-P – June 2003Motion Instructions 265At the top of the dialog, in the title bar, there is a number at the end of the

Strany 195

Publication 1784-UM003A-EN-P – June 2003266 Motion Instructions

Strany 196 - Right Mouse Click

267 Publication 1784-UM003A-EN-P – June 2003Chapter 13Motion Object AttributesThe Motion Object Attributes are included in this manual to provide you

Strany 197 - Copy/Paste

Publication 1784-UM003A-EN-P – June 2003268 Motion Object AttributesGroup InstanceThe Assigned Group Instance attribute is used to determine wh

Strany 198 - Cut/Paste

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 269C2C Connection InstanceWhen Axis Data Type is specified to be ‘Consumed’ th

Strany 199 - 1784-PM16SE motion module

Publication 1784-UM003A-EN-P – June 2003270 Motion Object AttributesAxis Configuration StateThe Axis Configuration State attribute is used for

Strany 200

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 271Motion Status AttributesThe Motion Status Attributes associated with the Ax

Strany 201 - Servo Drive Overview

Publication 1784-UM003A-EN-P – June 200320 SoftLogix ControllerSerial Port TabThe Serial Port tab allows you to view and configure the controll

Strany 202 - General Tab

Publication 1784-UM003A-EN-P – June 2003272 Motion Object AttributesCommand PositionCommand Position is the desired or commanded position of a

Strany 203

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 273Since the MGSP instruction simultaneously stores the actual and command pos

Strany 204 - Electronic Keying

Publication 1784-UM003A-EN-P – June 2003274 Motion Object AttributesFor example, on an axis with position units of inches and a conversion cons

Strany 205 - Requested Packet Interval

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 275Actual AccelerationActual Acceleration is the current instantaneously measu

Strany 206 - Inhibit Module Checkbox

Publication 1784-UM003A-EN-P – June 2003276 Motion Object AttributesRegistration PositionTwo registration position attributes are provided to i

Strany 207 - Associated Axes Tab

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 277Registration TimeThe two Registration Time values contain the lower 32-bits

Strany 208 - New Axis button

Publication 1784-UM003A-EN-P – June 2003278 Motion Object AttributesStrobe Master OffsetThe Strobe Master Offset is the position offset that wa

Strany 209 - Bus Regulator ID

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 279Motion Status Bit AttributesThis section describes the various Motion Axis

Strany 210 - Identification

Publication 1784-UM003A-EN-P – June 2003280 Motion Object AttributesJog StatusThe Jog Status bit attribute is set if a Jog motion profile is cu

Strany 211

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 281Position Cam Pending StatusThe Position Cam Pending Status bit attribute is

Strany 212 - Reset Module

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 21Stop BitsThe actual number of stop bits per character. Choose from 2 (ASCII only

Strany 213

Publication 1784-UM003A-EN-P – June 2003282 Motion Object AttributesAxis Status Bit AttributesServo Action StatusThe Servo Action Status bit at

Strany 214

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 283Axis Fault Bit AttributesAll of the fault bit attributes defined below can

Strany 215

Publication 1784-UM003A-EN-P – June 2003284 Motion Object AttributesThe fault bits are updated every coarse update period of the consuming Logi

Strany 216

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 285Watch Event Armed StatusThe Watch Event Armed Status bit attribute is set w

Strany 217

Publication 1784-UM003A-EN-P – June 2003286 Motion Object AttributesHome Event StatusThe Home Event Status bit attribute is set when a home eve

Strany 218

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 287Output Cam Transition StatusThe Output Cam Transition Status bit is set whe

Strany 219 - Editing the Ultra Drive

Publication 1784-UM003A-EN-P – June 2003288 Motion Object AttributesMotion Conversion ConfigurationConversion ConstantTo allow axis position to

Strany 220

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 289Rotary AxisWhen the Rotary Axis attribute is set true (1), it enables the r

Strany 221

Publication 1784-UM003A-EN-P – June 2003290 Motion Object AttributesActiveWhen active homing is chosen as the homing mode, the desired homing s

Strany 222 - Connection Tab

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 291Active HomingActive homing sequences, with the exception of the “Immediate”

Strany 223 - Inhibit Module

European Communities (EC) Directive ComplianceIf this product has the CE mark it is approved for installation within the European Union and EEA region

Strany 224

Publication 1784-UM003A-EN-P – June 200322 SoftLogix ControllerSystem Protocol TabThe System Protocol tab allows you to configure the controlle

Strany 225 - New Axis

Publication 1784-UM003A-EN-P – June 2003292 Motion Object AttributesWhen this sequence is performed, the axis moves in the specified Home Direc

Strany 226 - Power Tab - Ultra Drive

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 293Active Bi-directional Home with MarkerThis active homing sequence is useful

Strany 227 - Module Info Tab

Publication 1784-UM003A-EN-P – June 2003294 Motion Object AttributesActive Bi-directional Home with Switch then MarkerThis is the most precise

Strany 228 - Internal State Status

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 295When this sequence is performed in the Active Homing Mode, the axis moves i

Strany 229 - Configured

Publication 1784-UM003A-EN-P – June 2003296 Motion Object AttributesWhen this sequence is performed in the Active Homing Mode, the axis moves i

Strany 230

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 297When this sequence is performed in the Passive Homing Mode, an external age

Strany 231

Publication 1784-UM003A-EN-P – June 2003298 Motion Object AttributesIn most cases, Home Position is set to zero, although any value, within the

Strany 232

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 299Motion Dynamics ConfigurationMaximum SpeedThe value of the Maximum Speed at

Strany 233 - Editing the Kinetix Drive

Publication 1784-UM003A-EN-P – June 2003300 Motion Object AttributesProgrammed Stop ModeThe Programmed Stop Mode attribute value determines how

Strany 234 - General Tab

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 301Hard ShutdownWhen configured for Hard Shutdown, the axis is immediately pla

Strany 235 - Revision

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 23Error DetectionClick on one of the radio buttons to specify the error detection

Strany 236

Publication 1784-UM003A-EN-P – June 2003302 Motion Object AttributesFigure 13.6 Servo Loop with Servo AttributesPosition CommandPosition Comman

Strany 237

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 303Aux Position FeedbackAux Position Feedback is the current value of the posi

Strany 238

Publication 1784-UM003A-EN-P – June 2003304 Motion Object AttributesVelocity FeedbackVelocity Feedback is the actual velocity of the axis as es

Strany 239

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 305Acceleration FeedbackAcceleration Feedback is the actual velocity of the ax

Strany 240 - Bus Regulator Catalog Number

Publication 1784-UM003A-EN-P – June 2003306 Motion Object AttributesServo Status Bit AttributesThis section describes the various Servo Axis Ob

Strany 241

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 307Process StatusThe Process Status bit attribute is set when there is an axis

Strany 242

Publication 1784-UM003A-EN-P – June 2003308 Motion Object AttributesAxis Control Bit AttributesAbort Process RequestWhen the Abort Process bit

Strany 243

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 309Axis Response Bit AttributesAbort Process AcknowledgeWhen the Abort Process

Strany 244

Publication 1784-UM003A-EN-P – June 2003310 Motion Object AttributesServo Fault Bit AttributesThe Servo Fault Bits attribute is a collection of

Strany 245 - Configuring an 8720MC Drive

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 311Positive/Negative Hardware Overtravel FaultsIf either the Positive Hard Ove

Strany 246

Publication 1784-UM003A-EN-P – June 200324 SoftLogix ControllerDF1 Slave ParametersTransmit RetriesEnter the number of attempted transmits with

Strany 247

Publication 1784-UM003A-EN-P – June 2003312 Motion Object AttributesFor example, loss of channel quadrature for an encoder can be caused by phy

Strany 248 - Editing the 8720MC Drive

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 313All of the fault bit attributes defined below can be handled by the Control

Strany 249

Publication 1784-UM003A-EN-P – June 2003314 Motion Object AttributesTimer Event FaultIf the Timer Event Fault bit attribute is set it indicates

Strany 250

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 315Attribute Error IDThe Attribute Error ID is used to retain the ID of the se

Strany 251

Publication 1784-UM003A-EN-P – June 2003316 Motion Object AttributesTest Status The Test Status attribute returns status of the last run MRHD (

Strany 252

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 317Tune Acceleration/DecelerationTimeThe Tune Acceleration Time and Tune Decel

Strany 253

Publication 1784-UM003A-EN-P – June 2003318 Motion Object AttributesTune InertiaWhen the axis is configured for interface to a external torque

Strany 254 - Associated Axes Tab (8720MC

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 319When the Tune Inertia Bandwidth product reaches 4000 or greater, the LP fil

Strany 255 - Power Tab - 8720MC Drive

Publication 1784-UM003A-EN-P – June 2003320 Motion Object AttributesExternal software (RSLogix5000) also uses the current configured value for

Strany 256

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 321Fault Configuration BitsSoft Overtravel CheckingWhen the Soft Overtravel Ch

Strany 257

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 25Master TransmitChoose the master message transmit that designates when to send a

Strany 258

Publication 1784-UM003A-EN-P – June 2003322 Motion Object AttributesDrive Fault Normally ClosedThe Drive Fault Normally Closed bit attribute co

Strany 259

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 323Feedback Polarity NegativeThis Feedback Polarity Negative bit attribute con

Strany 260

Publication 1784-UM003A-EN-P – June 2003324 Motion Object AttributesPosition Servo with Torque ServoDriveThis configuration provides full posit

Strany 261 - Motion Instructions

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 325Velocity Servo with Torque ServoDriveThis configuration provides velocity s

Strany 262 - Motion Move Instructions

Publication 1784-UM003A-EN-P – June 2003326 Motion Object AttributesPosition Servo with Velocity ServoDriveThis configuration provides full pos

Strany 263 - Instructions

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 327Velocity Servo with Velocity ServoDriveThis configuration provides velocity

Strany 264 - Motion Coordinated Move

Publication 1784-UM003A-EN-P – June 2003328 Motion Object AttributesServo GainsThe 1784-PM02AE 2-Axis Servo module uses a Nested Digital Servo

Strany 265 - Commands

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 329Velocity Feedforward GainServo Drives require non-zero command input to gen

Strany 266

Publication 1784-UM003A-EN-P – June 2003330 Motion Object AttributesAcceleration Feedforward GainThe Acceleration Feedforward Gain attribute is

Strany 267 - Organizer

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 331Position Proportional GainThe Position Error is multiplied by the Position

Strany 268

Publication 1784-UM003A-EN-P – June 200326 SoftLogix ControllerToken Hold FactorA value between 1 and 4.User Protocol TabThe User Protocol tab

Strany 269

Publication 1784-UM003A-EN-P – June 2003332 Motion Object AttributesIn general, however, modern position servo systems typically run with at le

Strany 270 - Supported Commands

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 333In certain cases, Pos I Gain control is disabled. One such case is when the

Strany 271 - Motion Event

Publication 1784-UM003A-EN-P – June 2003334 Motion Object AttributesMaximum BandwidthThere are limitations to the maximum bandwidth that can be

Strany 272 - Motion Direct Command

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 335Velocity Integral GainWhen configured for a torque (current) loop servo dri

Strany 273 - Help Button

Publication 1784-UM003A-EN-P – June 2003336 Motion Object AttributesFor example, if this axis is using position units of motor revolutions (rev

Strany 274

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 337Output LP Filter BandwidthThe Output Filter Bandwidth attribute controls th

Strany 275 - Motion Object Attributes

Publication 1784-UM003A-EN-P – June 2003338 Motion Object AttributesNote: The software travel limits are not enabled until the selected homing

Strany 276 - C2C Map Instance

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 339The position lock tolerance value is interpreted as a ± quantity. For examp

Strany 277 - Axis Data Type

Publication 1784-UM003A-EN-P – June 2003340 Motion Object AttributesThe servo output limit may also be used if the drive cannot accept the full

Strany 278 - Motion Object Status

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 341Torque OffsetTorque Offset compensation can be used to provide a dynamic to

Strany 279 - Motion Status Attributes

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 27Termination Character 1 and 2Enter the characters that be used to define the end

Strany 280 - Strobe Position

Publication 1784-UM003A-EN-P – June 2003342 Motion Object AttributesServo Fault ConfigurationServo Fault ActionsEach axis can be configured to

Strany 281 - Average Velocity

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 343Disable DriveIf a fault action is set to Disable Drive, then when the assoc

Strany 282 - Command Velocity

Publication 1784-UM003A-EN-P – June 2003344 Motion Object AttributesTest IncrementThe Motor Feedback Test Increment attribute is used in conjun

Strany 283 - Watch Position

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 345Tuning TorqueThe Tuning Torque attribute value determines the maximum torqu

Strany 284 - Registration Position

Publication 1784-UM003A-EN-P – June 2003346 Motion Object AttributesVelocity Servo BandwidthThe value for the Velocity Servo Bandwidth represen

Strany 285 - Master Offset

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 347Position Servo BandwidthThe value for the Position Servo Bandwidth represen

Strany 286 - Start Master Offset

Publication 1784-UM003A-EN-P – June 2003348 Motion Object AttributesTune Position Error IntegratorThe Tune Position Error Integrator bit attrib

Strany 287 - Motion Status Bit Attributes

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 349Since Drive Status Attributes values are resident in the drive, these value

Strany 288

Publication 1784-UM003A-EN-P – June 2003350 Motion Object AttributesPosition CommandPosition Command is the current value of the Fine Command P

Strany 289 - Master Offset Move Status

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 351Velocity ErrorVelocity Error is the difference, in configured axis Position

Strany 290 - Shutdown Status

Publication 1784-UM003A-EN-P – June 200328 SoftLogix ControllerThis option is disabled when the Control Line option is configured for Half Dupl

Strany 291 - Module Fault Bit Attribute

Publication 1784-UM003A-EN-P – June 2003352 Motion Object AttributesAcceleration CommandAcceleration Command is the current acceleration refere

Strany 292 - Axis Event Bit Attributes

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 353Pos./Neg. Dynamic Torque LimitThese parameters represent the currently oper

Strany 293

Publication 1784-UM003A-EN-P – June 2003354 Motion Object AttributesDC Bus VoltageThis parameter is the present voltage on the DC Bus of the dr

Strany 294 - Output Cam Lock Status

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 355Drive Status Bit AttributesGSV/SSV Access Attribute Name Data Type ValuesGS

Strany 295 - Motion Unit Configuration

Publication 1784-UM003A-EN-P – June 2003356 Motion Object AttributesServo Action StatusThe Servo Action Status bit attribute is set when servo

Strany 296 - Configuration

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 357Enable Input StatusThe Enable Input Status bit attribute represents the cur

Strany 297 - Motion Homing

Publication 1784-UM003A-EN-P – June 2003358 Motion Object AttributesPosition Lock StatusThe Position Lock Status bit attribute is set when the

Strany 298 - Absolute

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 359Change Cmd Reference The Change Command Reference bit attribute is set when

Strany 299 - Active Immediate Home

Publication 1784-UM003A-EN-P – June 2003360 Motion Object AttributesChange Pos ReferenceThe Change Position Reference bit attribute is set when

Strany 300

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 361. GSV/SSV Access Attribute Name Data Type ValuesGSV Drive Fault Bits DINT D

Strany 301

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 29Number of Major Faults Since Last ClearedDisplays the number of major fault even

Strany 302

Publication 1784-UM003A-EN-P – June 2003362 Motion Object AttributesPositive/Negative Software Overtravel FaultsIf either the Positive Soft Ove

Strany 303

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 363Feedback 1 or Feedback 2 Noise FaultIf the Feedback Noise Fault bit attribu

Strany 304 - Passive Home with Marker

Publication 1784-UM003A-EN-P – June 2003364 Motion Object AttributesDrive Overtemperature FaultThe Drive Overtemperature Fault bit is set when

Strany 305 - Home Position

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 365Power Phase Loss FaultThe Power Phase Loss Fault bit is set when the drive

Strany 306 - Home Return Speed

Publication 1784-UM003A-EN-P – June 2003366 Motion Object AttributesControl Sync FaultThe Control Sync Fault bit attribute is set when the Logi

Strany 307 - Motion Dynamics

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 367Drive Warning Bit AttributesAll of the warning bit attributes defined below

Strany 308 - Fast Shutdown

Publication 1784-UM003A-EN-P – June 2003368 Motion Object AttributesAttribute Error CodeWhen an Axis Configuration Fault occurs, one or more ax

Strany 309 - Servo Status Attributes

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 369Commissioning Status AttributesThe list of Commissioning Status Attributes

Strany 310 - Position Feedback

Publication 1784-UM003A-EN-P – June 2003370 Motion Object AttributesTest Direction ForwardThe Test Direction Forward attribute reports the dire

Strany 311 - Velocity Command

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 371Tune Acceleration/DecelerationThe Tune Acceleration Time and Tune Decelerat

Strany 312 - Acceleration Command

Publication 1784-UM003A-EN-P – June 200330 SoftLogix ControllerRecent FaultsDisplays a description of the last eight minor faults that have occ

Strany 313 - Marker Distance

Publication 1784-UM003A-EN-P – June 2003372 Motion Object AttributesEnhancements have been made to the Logix tuning algorithm to address excess

Strany 314 - Servo Status Bit Attributes

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 373Drive ConfigurationThe Drive Configuration attributes provide basic drive c

Strany 315

Publication 1784-UM003A-EN-P – June 2003374 Motion Object AttributesServo Loop ConfigurationThe Servo Loop Configuration attribute determines t

Strany 316

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 375 Fault Configuration BitsGSV/SSV Access Attribute Name Data Type ValuesGSV

Strany 317

Publication 1784-UM003A-EN-P – June 2003376 Motion Object AttributesSoft Overtravel CheckingWhen the Soft Overtravel Checking bit is set it ena

Strany 318 - Servo Fault Bit Attributes

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 377Advanced Scaling AttributesThe advanced attributes are derived from the Dri

Strany 319 - Feedback Noise Fault

Publication 1784-UM003A-EN-P – June 2003378 Motion Object AttributesDrive PolarityCustom PolarityCustom Polarity is used to enable custom polar

Strany 320 - Module Fault Bit Attributes

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 379Advanced Polarity AttributesThe Advanced Polarity Attributes are derived fr

Strany 321 - Module Sync Fault

Publication 1784-UM003A-EN-P – June 2003380 Motion Object AttributesAxis Info SelectAxis Info Select attributes are used to enable periodic dat

Strany 322 - Attribute Error Code

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 381Motor DataThe Motor Data attribute is a structure with a length element and

Strany 323 - Commissioning Status

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 31DateThe wall clock date, in the format currently selected in the Regional Settin

Strany 324 - Tune Status

Publication 1784-UM003A-EN-P – June 2003382 Motion Object AttributesAdvanced Feedback AttributesThe Advanced Feedback Attributes map directly t

Strany 325 - Tune Rise Time

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 383Motor Position ServoThe Motor Position Servo configuration provides full po

Strany 326 - Tune Inertia

Publication 1784-UM003A-EN-P – June 2003384 Motion Object AttributesAuxiliary Position ServoThe Auxiliary Position Servo configuration provides

Strany 327 - Servo Configuration

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 385Dual Position ServoThis configuration provides full position servo control

Strany 328 - External Drive Type

Publication 1784-UM003A-EN-P – June 2003386 Motion Object AttributesMotor Dual Command ServoThe Motor Dual Command Servo configuration provides

Strany 329 - Drive Fault Checking

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 387Auxiliary Dual Command ServoThe Motor Dual Command Servo configuration prov

Strany 330 - Servo Polarity Bits

Publication 1784-UM003A-EN-P – June 2003388 Motion Object AttributesVelocity ServoThe Velocity Servo configuration provides velocity servo cont

Strany 331 - Servo Loop Block Diagrams

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 389Torque ServoThe Torque Servo configuration provides torque servo control us

Strany 332 - Servo Config = Position

Publication 1784-UM003A-EN-P – June 2003390 Motion Object AttributesPosition Proportional GainThe Position Error is multiplied by the Position

Strany 333 - Servo Config = Velocity Servo

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 391In general, modern position servo systems typically run with a unit gain ba

Strany 335

Publication 1784-UM003A-EN-P – June 200332 SoftLogix ControllerAll of the circular indicators are clear when you are offline.Advanced TabThe Ad

Strany 336

Publication 1784-UM003A-EN-P – June 2003392 Motion Object AttributesIn certain cases, Pos I Gain control is disabled. One such case is when the

Strany 337 - Velocity Feedforward Gain

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 393The optimal value for Velocity Feedforward Gain is 100% theoretically. In r

Strany 338 - Acceleration Feedforward Gain

Publication 1784-UM003A-EN-P – June 2003394 Motion Object AttributesThe optimal value for Acceleration Feedforward is 100% theoretically. In re

Strany 339 - Bandwidth Method

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 395In general, modern velocity servo systems typically run with a unit gain ba

Strany 340 - Position Integral Gain

Publication 1784-UM003A-EN-P – June 2003396 Motion Object AttributesWhile the Vel I Gain, if employed, is typically established by the automati

Strany 341 - Velocity Proportional Gain

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 397The output filter is particularly useful in high inertia applications where

Strany 342

Publication 1784-UM003A-EN-P – June 2003398 Motion Object AttributesAdvanced Drive Gain AttributesThe above advanced attributes map directly to

Strany 343 - Velocity Integral Gain

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 399For example, specifying a position error tolerance of 0.75 Position Units m

Strany 344

Publication 1784-UM003A-EN-P – June 2003400 Motion Object AttributesAdvanced Drive LimitsThe advanced attributes map directly to SERCOS IDNs. T

Strany 345 - Servo Limits

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 401Velocity OffsetVelocity Offset compensation can be used to correct to provi

Strany 346

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 33Controller Fault HandlerChoose the program that runs as the result of a system f

Strany 347

Publication 1784-UM003A-EN-P – June 2003402 Motion Object AttributesShutdownIf a fault action is set to Disable Drive, then when the associated

Strany 348 - Servo Offsets

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 403Status OnlyIf a fault action is set to Status Only, then when the associate

Strany 349

Publication 1784-UM003A-EN-P – June 2003404 Motion Object AttributesBrake Release DelayThe Brake Release Delay attribute controls the amount of

Strany 350 - Servo Fault Configuration

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 405Commissioning Configuration AttributesThe Axis Object provides sophisticate

Strany 351 - Commissioning

Publication 1784-UM003A-EN-P – June 2003406 Motion Object AttributesTuning SpeedThe Tuning Speed attribute value determines the maximum speed o

Strany 352 - Tuning Speed

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 407Damping FactorThe Damping Factor attribute value is used in calculating the

Strany 353 - Drive Model Time Constant

Publication 1784-UM003A-EN-P – June 2003408 Motion Object AttributesThere are practical limitations to the maximum Velocity Servo Bandwidth for

Strany 354 - Velocity Servo Bandwidth

Publication 1784-UM003A-EN-P – June 2003Motion Object Attributes 409Tuning Configuration Bits Tuning Direction ReverseThe Tune Direction Revers

Strany 355 - Tuning Direction Reverse

Publication 1784-UM003A-EN-P – June 2003410 Motion Object AttributesTune Output Low-Pass FilterThe Tune Output Low-Pass Filter bit attribute de

Strany 356 - Servo Drive Status

411 Publication 1784-UM003A-EN-P – June 2003Chapter 14TroubleshootingThis chapter describes how to troubleshoot your SoftLogix motion control system u

Strany 357

Publication 1784-UM003A-EN-P – June 200334 SoftLogix ControllerExecution ControlThis determines the execution model for the SFC. Your options a

Strany 358

Publication 1784-UM003A-EN-P – June 2003412 TroubleshootingAt start up the LED goes through a sequence of color changes:• At power up LED is Gr

Strany 359

Publication 1784-UM003A-EN-P – June 2003Troubleshooting 413Below the SERCOS Ring Status LED is the CP LED. The CP LED shows the communication p

Strany 360 - Torque Feedback

Publication 1784-UM003A-EN-P – June 2003414 TroubleshootingCard Status Using the OK IndicatorThe SERCOS Ring Status LEDThe SERCOS Ring Status L

Strany 361

Publication 1784-UM003A-EN-P – June 2003Troubleshooting 415SERCOS Ring Status The Communication Phase LEDThe Communication Phase (CP) LED provi

Strany 362 - Torque Limit Source

Publication 1784-UM003A-EN-P – June 2003416 TroubleshootingSERCOS Communication Phase Status Using the CP IndicatorIf the CP LED displays: Then

Strany 363 - Drive Status Bit Attributes

417 Publication 1784-UM003A-EN-P – June 2003Appendix ASpecifications and Performance This appendix shows specifications and performance guidelines for

Strany 364

Publication 1784-UM003A-EN-P – June 2003418 Specifications and Performance1784-M16SE Motion Card Specifications OK and Enable OutputsTypeOperat

Strany 365

Publication 1784-UM003A-EN-P – June 2003Specifications and Performance 419Glass Fiber Optic SpecificationsTransmission RangeCore DiameterCladdi

Strany 366

Publication 1784-UM003A-EN-P – June 2003420 Specifications and Performance

Strany 367

421 Publication 1784-UM003A-EN-P – June 2003Appendix B Wiring DiagramsThis appendix shows the loop interconnect diagrams for common motion configurati

Strany 368 - Drive Fault Bit Attributes

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 35File TabThe File tab displays information about the project file.The fields on t

Strany 369

Publication 1784-UM003A-EN-P – June 2003422 Wiring DiagramsUsing a 1784-PM02AE Module With aTorque Servo DriveFigure B.1 Torque Servo Drive

Strany 370

Publication 1784-UM003A-EN-P – June 2003Wiring Diagrams 423Using a 1784-PM02AE Module With aVelocity Servo DriveFigure B.2 Velocity Servo Drive

Strany 371 - Overload Fault

Publication 1784-UM003A-EN-P – June 2003424 Wiring Diagramsfor wiring drives, encoders, etc. A termination panel, mounted separately from the c

Strany 372

Publication 1784-UM003A-EN-P – June 2003Wiring Diagrams 425Figure 5 P2 ConnectorP3 and P4The P3/P4 receptacles are for wiring the axes. P3 is

Strany 373 - SERCOS Fault

Publication 1784-UM003A-EN-P – June 2003426 Wiring Diagrams1784-PM02AE-TP0x CableThe 1784-PM02AE card is connected to the termination panel via

Strany 374 - SERCOS Ring Fault

Publication 1784-UM003A-EN-P – June 2003Wiring Diagrams 427Sync CableUp to four (4) 1784-PM02AE cards may be installed in a single computer pro

Strany 375 - Cooling Error Warning

Publication 1784-UM003A-EN-P – June 2003428 Wiring Diagrams1398 to Termination Panel WiringDiagramThis is a general wiring example of the 1398

Strany 376 - SERCOS Error Code

Publication 1784-UM003A-EN-P – June 2003 429Symbols(Brackets) 181Numerics1394C Drive moduleAssociated Axes Tab 199New Axis button 200Node X0 200

Strany 377

Publication 1784-UM003A-EN-P – June 2003 430 Description 67Electronic Keying 68Compatible Module 68Exact Match 68Name 67Revision 68Slot 68Statu

Strany 378

Publication 1784-UM003A-EN-P – June 2003 431Filters 108Family 108Feedback Type 108Voltage 108Dynamics Tab 126Manual Adjust 128Maximum Accelerati

Strany 379

Publication 1784-UM003A-EN-P – June 200336 SoftLogix ControllerRedundancy TabThe Redundancy Tab is only present if the specified processor type

Strany 380 - Servo Drive Configuration

Publication 1784-UM003A-EN-P – June 2003 432 Position Error Tolerance 149Position Lock Tolerance 150Soft Travel Limits 149Limits Tab (AXIS_SERV

Strany 381 - Axis Type

Publication 1784-UM003A-EN-P – June 2003 433Commissioning Status Attributes 315, 369Test Direction Forward 316, 370Test Status 316, 369Tune Acce

Strany 382 - Advanced Servo Configuration

Publication 1784-UM003A-EN-P – June 2003 434 Drive Fault Inputs 321Drive Limits 398Advanced Drive Limits 400Maximum Positive/Negative Travel 39

Strany 383

Publication 1784-UM003A-EN-P – June 2003 435Transmit Retries 24DH485 Parameters 25Max Station Address 25Token Hold Factor 26Normal Poll Group Si

Strany 384 - Custom Scaling

Publication 1784-UM003A-EN-P – June 2003 436 Ellipsis (...) 232New Axis 232Node 232Connection Tab 229Major Fault 230Module Fault 231Connection

Strany 385 - Advanced Scaling Attributes

Publication 1784-UM003A-EN-P – June 2003 437Motion Arm Registration (MAR) 255Motion Arm Watch Position (MAW) 255Motion Disarm Output Cam (MDOC)

Strany 386 - Positive/Negative Polarity

Publication 1784-UM003A-EN-P – June 2003 438 Strobe Master Offset 278Strobe Position 272Watch Position 275Motion Status Bit Attributes 279Axis

Strany 387 - Advanced Polarity Attributes

Publication 1784-UM003A-EN-P – June 2003 439Acceleration Feedforward Gain 330Axis Info Select 322Axis Type 319Bandwidth Method 331External Drive

Strany 388 - Motor and Feedback

Publication 1784-UM003A-EN-P – June 2003 440 Positive Overtravel Input Status 356Power Limit Status 358Process Status 356Registration 1/2 Input

Strany 389 - Aux Feedback Ratio

Publication 1784-UM003A-EN-P – June 2003 441Change Cmd Reference 308Shutdown Request 308Zero DAC Request 308Axis Response Bit Attributes 309Abor

Strany 390

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 374 – Primary with no partner8 – Synchronized Secondary 9 – Disqualified Secondary

Strany 391 - Motor Position Servo

Publication 1784-UM003A-EN-P - June 2003 1 PN 957400-34Copyright © 2003 Rockwell Automation. All rights reserved. Printed in USA.For more information

Strany 392 - Auxiliary Position Servo

Rockwell Automation SoftLogix PCI Motion CardSetup and Configuration Manual

Strany 393 - Dual Position Servo

Publication 1784-UM003A-EN-P – June 200338 SoftLogix ControllerPartner StatusThis section shows information on the status of the Partner module

Strany 394 - Motor Dual Command Servo

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 39Advanced ButtonThe Advanced Button displays configuration parameters for retaini

Strany 395 - Auxiliary Dual Command Servo

Publication 1784-UM003A-EN-P – June 200340 SoftLogix ControllerClick on the Load/Store button to access the Nonvolatile Memory Load/Store dialo

Strany 396 - Velocity Servo

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 41Figure 2.16 Controller Properties Nonvolatile Memory TabNameThe name of the stor

Strany 397 - Drive Gains

i Publication 1784-UM003A-EN-P – June 2003 Table of ContentsPrefaceUsing This ManualWho Should Use This Manual. . . . . . . . . . . . . . . . . . . .

Strany 398

Publication 1784-UM003A-EN-P – June 200342 SoftLogix ControllerLoad ImageThe condition under which the image stored in nonvolatile memory is lo

Strany 399

Publication 1784-UM003A-EN-P – June 2003SoftLogix Controller 43StoredThe workstation date and time when the image was stored in nonvolatile mem

Strany 400

Publication 1784-UM003A-EN-P – June 200344 SoftLogix Controller

Strany 401

45 Publication 1784-UM003A-EN-P – June 2003Chapter 3Adding and Configuring Your 1784-PM02AE Motion ModuleThis chapter describes how to add, configure,

Strany 402

Publication 1784-UM003A-EN-P – June 200346 Adding and Configuring Your 1784-PM02AE Motion Module2. Select New Module. The Select Module Type wi

Strany 403

Publication 1784-UM003A-EN-P – June 2003Adding and Configuring Your 1784-PM02AE Motion Module 473. Click on the Clear All button to clear the d

Strany 404 - Output Notch Filter Frequency

Publication 1784-UM003A-EN-P – June 200348 Adding and Configuring Your 1784-PM02AE Motion ModuleMajor RevisionSelect the major revision number

Strany 405 - Integrator Hold Enable

Publication 1784-UM003A-EN-P – June 2003Adding and Configuring Your 1784-PM02AE Motion Module 495. Select OK. The Module Create Wizard displays

Strany 406 - Drive Limits

Publication 1784-UM003A-EN-P – June 200350 Adding and Configuring Your 1784-PM02AE Motion Module7. Press the Next button to proceed to the next

Strany 407 - Figure 13.25 Position Error

Publication 1784-UM003A-EN-P – June 2003Adding and Configuring Your 1784-PM02AE Motion Module 519. This screen lets you associate an axis with

Strany 408 - Drive Offsets

Publication 1784-UM003A-EN-P – June 2003 iiChapter 4Configuring the1784-PM16SE CardAdding the 1784-PM16SE. . . . . . . . . . . . . . . . . . .

Strany 409 - Drive Fault Actions

Publication 1784-UM003A-EN-P – June 200352 Adding and Configuring Your 1784-PM02AE Motion ModuleThis accesses the Module Properties screen. The

Strany 410 - Stop Command

Publication 1784-UM003A-EN-P – June 2003Adding and Configuring Your 1784-PM02AE Motion Module 53The name must be IEC 1131-3 compliant. If you

Strany 411 - Brake Engage Delay

Publication 1784-UM003A-EN-P – June 200354 Adding and Configuring Your 1784-PM02AE Motion ModuleWhen you insert a module into a slot in a Contr

Strany 412 - Drive Power Attributes

Publication 1784-UM003A-EN-P – June 2003Adding and Configuring Your 1784-PM02AE Motion Module 55Inhibit Module checkboxCheck/Uncheck this box t

Strany 413

Publication 1784-UM003A-EN-P – June 200356 Adding and Configuring Your 1784-PM02AE Motion ModuleModule FaultDisplays the fault code returned fr

Strany 414

Publication 1784-UM003A-EN-P – June 2003Adding and Configuring Your 1784-PM02AE Motion Module 57Servo Update PeriodSelects the periodic rate at

Strany 415

Publication 1784-UM003A-EN-P – June 200358 Adding and Configuring Your 1784-PM02AE Motion ModuleThe data on this tab comes directly from the mo

Strany 416

Publication 1784-UM003A-EN-P – June 2003Adding and Configuring Your 1784-PM02AE Motion Module 59Major/Minor Fault StatusInternal State StatusTh

Strany 417

Publication 1784-UM003A-EN-P – June 200360 Adding and Configuring Your 1784-PM02AE Motion ModuleModule IdentityThis field does not take into ac

Strany 418 - Tune Output Low-Pass Filter

61 Publication 1784-UM003A-EN-P – June 2003Chapter 4Configuring the1784-PM16SE CardAdding the 1784-PM16SEThis chapter reviews the necessary steps for

Strany 419 - Troubleshooting

Publication 1784-UM003A-EN-P – June 2003 iiiChapter 12Motion InstructionsMotion State Instructions . . . . . . . . . . . . . . . . . . . . .

Strany 420 - Indicators

Publication 1784-UM003A-EN-P – June 200362 Configuring the1784-PM16SE Card3. The Select Module Type screen displays. Select Clear All. Select M

Strany 421 - The OK LED

Publication 1784-UM003A-EN-P – June 2003Configuring the1784-PM16SE Card 636. The Create Module Wizard opens.Figure 4.4 Module Properties Wizard

Strany 422 - The SERCOS Ring Status LED

Publication 1784-UM003A-EN-P – June 200364 Configuring the1784-PM16SE Card8. The Connection Screen Wizard displays.Figure 4.5 Module Properties

Strany 423 - The Communication Phase LED

Publication 1784-UM003A-EN-P – June 2003Configuring the1784-PM16SE Card 6510. The SERCOS interface screen displays.Figure 4.6 Module Properties

Strany 424 - 416 Troubleshooting

Publication 1784-UM003A-EN-P – June 200366 Configuring the1784-PM16SE CardSERCOS interface Motion Card OverviewThe 1784-PM16SE SERCOS interface

Strany 425 - Specifications

Publication 1784-UM003A-EN-P – June 2003Configuring the1784-PM16SE Card 67Editing 1784-PM16SE Card Properties General TabUse this tab to create

Strany 426 - 1784-M16SE Motion Card

Publication 1784-UM003A-EN-P – June 200368 Configuring the1784-PM16SE CardSlotEnter the slot number where the card resides. The spin button con

Strany 427

Publication 1784-UM003A-EN-P – June 2003Configuring the1784-PM16SE Card 69Status – This is a Read Only field that displays the Controllers curr

Strany 428

Publication 1784-UM003A-EN-P – June 200370 Configuring the1784-PM16SE CardConnection TabThe Connection Tab reflects controller to card behavior

Strany 429 - Wiring Diagrams

Publication 1784-UM003A-EN-P – June 2003Configuring the1784-PM16SE Card 71When you check this box and go online, the icon representing this car

Strany 430 - Torque Servo Drive

Publication 1784-UM003A-EN-P – June 2003 ivChapter 14Troubleshooting1784-PM02AE LED Indicator . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 431

Publication 1784-UM003A-EN-P – June 200372 Configuring the1784-PM16SE Card• Service Request Error - The controller is attempting to request a s

Strany 432 - 424 Wiring Diagrams

Publication 1784-UM003A-EN-P – June 2003Configuring the1784-PM16SE Card 73The SERCOS ring consists of the drives and axes connected to the 1784

Strany 433 - P3 and P4

Publication 1784-UM003A-EN-P – June 200374 Configuring the1784-PM16SE CardTransmit PowerSelect the optic transmit power range for the SERCOS ri

Strany 434 - 1784-PM02AE-TP0x Cable

Publication 1784-UM003A-EN-P – June 2003Configuring the1784-PM16SE Card 75Fault TypeDisplays the current fault type, if any, on the SERCOS ring

Strany 435 - Sync Cable

Publication 1784-UM003A-EN-P – June 200376 Configuring the1784-PM16SE CardThe data on this tab comes directly from the card. If you selected a

Strany 436 - 428 Wiring Diagrams

Publication 1784-UM003A-EN-P – June 2003Configuring the1784-PM16SE Card 77Major/Minor Fault Status Internal State StatusThis field displays th

Strany 437 - Numerics

Publication 1784-UM003A-EN-P – June 200378 Configuring the1784-PM16SE CardModule Identity This field does not take into account the Electronic

Strany 438 - 430

79 Publication 1784-UM003A-EN-P – June 2003Chapter 5The Motion GroupCreating A Motion GroupEach .acd program must have one motion group. (There can be

Strany 439 - 431

Publication 1784-UM003A-EN-P – June 200380 The Motion Group3. Click on the respective radio button to select one of the following tag types:• B

Strany 440 - 432

Publication 1784-UM003A-EN-P – June 2003The Motion Group 81The Motion Group Wizard group - Axis Assignment screen displays. Figure 5.3 Motion G

Strany 441 - 433

1 Publication 1784-UM003A-EN-P – June 2003PrefaceUsing This ManualWho Should Use This ManualTo use this manual, you should be able to program and oper

Strany 442 - 434

Publication 1784-UM003A-EN-P – June 200382 The Motion GroupEditing the Motion Group PropertiesThe Motion Group properties can be edited by righ

Strany 443 - 435

Publication 1784-UM003A-EN-P – June 2003The Motion Group 83Axis Assignment TabThe Axis Assignment screen is where axes are either assigned or u

Strany 444 - 436

Publication 1784-UM003A-EN-P – June 200384 The Motion GroupWhen RSLogix 5000 software is online, all of the attributes on this tab transition t

Strany 445 - 437

Publication 1784-UM003A-EN-P – June 2003The Motion Group 85Tag TabUse this tab to modify the name and description of the group. Figure 5.7 Moti

Strany 446 - 438

Publication 1784-UM003A-EN-P – June 200386 The Motion GroupData Type (read-only)The axis data type: MOTION_GROUPScopeDisplays the scope of the

Strany 447 - 439

87 Publication 1784-UM003A-EN-P – June 2003Chapter 6Naming & Configuring Your Motion AxisThis chapter describes how to name, configure, and edit y

Strany 448 - 440

Publication 1784-UM003A-EN-P – June 200388 Naming & Configuring Your Motion AxisYou can also right click on the Motion Group and select New

Strany 449 - 441

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 89The New Tag window appears.Figure 6.4 New Tag DialogIf you

Strany 450

Publication 1784-UM003A-EN-P – June 200390 Naming & Configuring Your Motion AxisYou must set up only one consumed tag to get data from the

Strany 451

Publication 1784-UM003A-EN-P – June 2003Naming & Configuring Your Motion Axis 91Data TypeIn the Data Type field you can either enter the ty

Komentáře k této Příručce