Administering Report Expert Chapter 9
Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014 141
Use this setting: To modify:
Changes with Report Server (page 163)" for more
information.
RSBizWareHost The name of the Information Services Manager host.
The default setting (NULL) indicates that this field on the
Report Expert software is empty.
To learn how to complete the field in order to include the
Quick Web tab in the Report Expert client, see "Configuring
the Quick Web (page 149)".
RSBizWareHttpPort The HTTP port number used by the Information Services
Manager computer.
The default setting (NULL) indicates that this field in the
Report Expert software is empty.
To learn how to complete the field in order to include the
Quick Web tab in the Report Expert client, see "Configuring
the Quick Web (page 149)".
StateDetailRowLimit The maximum number of rows to be taken from the
database when the StateDetail query is executed.
If this setting is blank or set to 0, the parameter has no
effect.
If you type a value for this setting and the generated report
exceeds the number of rows indicated, the Max row limit
reached message appears in the resulting report. See "State
Detail Report Template (page 65)" for more information.
Performance note: This setting limits the size of the
dataset included in the report. A lower number results in
faster reports. However, a lower number may also result in
incomplete reports if the limit is exceeded. Therefore, this
setting is a trade-off and depends upon how much data is
needed for the Root Cause Analysis and State Detail reports
that use the StateDetail query. This setting does not have
any impact on reports that use other queries.
TopN The maximum number that users can type in the TopN
section of the Parameter Set pane in Report Expert. If this
setting has no entry in the RptSetting table, the value is set
to 20.
See "Using the TOP N Parameter (page 93)" for more
information.
ThresholdBestBeyond The limit of the OEE% value, after which the color from the