Editing Event and Production Data Chapter 8
Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014 105
The Event details panel contains the following items:
Item Description
Activity Area The name of the activity area.
Category – Name The category and name of the selected event.
Start Time
End Time
The time the event started/ended.
Start Value
End Value
The numeric or string value collected when the event
started/ended.
If a Value Lookup List has been defined for the selected event, the
values in these fields show the values chosen from the list.
Duration The length of the event, calculated as the difference between the
start time and end time and displayed using the format
HH:MM:SS.mmm.
Reporting Value The event value which will be used in reports.
Records The number of records written in the FactoryTalk Metrics database
for the selected event. The value in this field is automatically
assigned when saving the event.
ID The ID of the event in the FactoryTalk Metrics database. The value
of this field is automatically assigned when saving the event.
Comments Additional comments on the event.
To display the details of the desired event, click the row of the event
in the Event list panel.
In the Event list panel, you can perform the following actions:
• View the list of events loaded from the FactoryTalk Metrics
database.
• Display the details of selected events.
• Create and delete events.
• Edit, split, and copy events.
Event List Panel