Rockwell-automation 20B PowerFlex 70, PowerFlex 700 Reference Manual Uživatelský manuál Strana 25

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 214
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 24
Analog Inputs
Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013 25
Configuration #5:
[Anlg In Config], bit 0 = “0” (Voltage)
[Speed Ref A Sel] = “Analog In 1”
[Speed Ref A Hi] = 60 Hz
[Speed Ref A Lo] = 0 Hz
[Analog In 1 Hi] = 5V
[Analog In 1 Lo] = 0V
This configuration is used when the input signal is 0-5 volts. Here, minimum
input (0 Volts) represents 0 Hz and maximum input (5 Volts) represents 60 Hz.
This allows full scale operation from a 0-5 volt source.
Analog Scaling
[Speed Reference A Sel] = “Analog In 1”
[Analog In 1 Hi]
10V
[Speed Ref A Hi]
0 Hz
[Analog In 1 Lo]
0V
[Speed Ref A Lo]
60 Hz
Analog Scaling
[Speed Reference A Sel] = “Analog In 1”
[Analog In 1 Hi]
5V
[Speed Ref A Hi]
60 Hz
[Analog In 1 Lo]
0V
[Speed Ref A Lo]
0Hz
2
4
6
8
10
601218
Output Hertz
Input Volts
24 30 364248 54 60
1
2
3
4
5
6
601218
Output Hertz
Input Volts
24 30 36 42 48 54 60
Zobrazit stránku 24