INTRODUCTION
PURPOSE
The
MHB44IND
module
(Figure
1
-
1)
supports
four
pulsed
voltage
inputs
for
interfacing
with
field
detectors,
and
supplies
0
-
22mA
analogue
outputs
for
process
control.
The
module
is
a rack
mounted,
9U
high
unit
that
provides
the
output
control
interface
between
the
SC300E
processing
environment
and
the
user
field
environment.
It
has
four
current
loop
output
channels.
All
field
inputs
and
outputs
are
galvanically
isolated
from
the
SC300E
system
but
have
a common
supply
connection.
Circuit
triplication
and
voting
procedures
make
the
module
single
-
fault
tolerant
and
latent
testing
ensures
that
the
failure
of
a channel
will
be
recogised
and
reported
to
the
SC300E
syste
m.
Front
panel
indicators
show
the
state
of
the
circuit
‘on
-
line’
status
and
the
health
of
the
module.
Sockets
are
provided
on
the
front
panel
for
monitoring
the
outputs.
The
module
is
compatible
with
‘dual
slot
hot
repair’,
and
can
be
fitted
in
any
of
the
ten
I/O
slots
in
the
SC300E
chassis.
‘Wrong
slotting’
is
prevented
by
physical
coding.
The
SC300E
system
software
identifies
the
module
via
a built
-
in
hardware
identifier.
Channel
outputs
leave
the
module
via
the
DIN
41612
‘rear
plug
-
up’
system
on
the
chassis
backplane.
This
document
is
intended
to
provide
a general
understanding
of
the
MHB44IND
sufficient
to
enable
basic
maintenance
procedures
to
be
effected
in
the
field.
ASSOCIATED DOCUMENTATION
Reference
No
Title
008
-
5097
Chassis
User
Manual
008
-
5201
TPH44AIC
4
-
Channel
Pulse
Input
and
Analogue
Output
Termination
Card
User
Manual
008-5108
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - (MHB44IND)

Triguard SC300E MHB44IND Pulse Input and Analogue Output Module (MHB44IND) Issue 2October 2005 INTRODUCTION PURPOSE The MHB44IND module (Figure 1-1) s

Strany 2

10MHB44INDOctober2005–Issue 2Triguard SC300EVoting operates so that the LFD deviations do not appear on the combined output. If a fault causes health

Strany 3

MHB44INDOctober2005–Issue211Triguard SC300E MHB44IND Pulse Input and Analogue Output Module Pulse Inputs The overall period of one or more cycles of t

Strany 4

12MHB44INDOctober2005–Issue 2Triguard SC300EAnalogue outputs Five test-sockets are provided for monitoring the output lines: one common terminal via 2

Strany 5

MHB44INDOctober2005–Issue213Triguard SC300E MHB44IND Pulse Input and Analogue Output Module Common interface The three discrete control circuits in th

Strany 6 - DESCRIPTIO

14MHB44INDOctober2005–Issue 2Triguard SC300ESUPPLEMENTARY INFORMATION Connector J1 is the I/O bus. Field output connectors J2 and J3 are in parallel.

Strany 7

MHB44INDOctober2005–Issue215Triguard SC300E MHB44IND Pulse Input and Analogue Output Module The connectors on J2 that are reserved for future use are

Strany 8

16MHB44INDOctober2005–Issue 2Triguard SC300ESERVICING SCOPE System repair is by module replacement. Faulty modules are not repairable in the field. Th

Strany 9 - Common functions

MHB44INDOctober2005–Issue217Triguard SC300E MHB44IND Pulse Input and Analogue Output Module REMOVAL AND REPLACEMENT CAUTION 4Failure to take the fault

Strany 10 - Triguard

18MHB44INDOctober2005–Issue 2Triguard SC300Ethe module into position. Some resistance will be felt as the rear connector pins engage. The module shoul

Strany 11 - Pulse Inputs

MHB44INDOctober2005–Issue219Triguard SC300E MHB44IND Pulse Input and Analogue Output Module 2. Operate the On/Off Line Request switch on the new modul

Strany 12 - Analogue outputs

2MHB44INDOctober2005–Issue 2Triguard SC300E

Strany 13 - Common interface

20MHB44INDOctober2005–Issue 2Triguard SC300ESPARE PARTS Spare parts and technical advice can be obtained from your local area offices.

Strany 14

MHB44INDOctober2005–Issue23Triguard SC300E MHB44IND Pulse Input and Analogue Output Module Mechanical coding block (Upper) Links JP1 to JP4 Links LK1

Strany 15

4MHB44INDOctober2005–Issue 2Triguard SC300ESPECIFICATION Model MHB44IND Channels 4 x pulse inputs 4 x analogue outputs Architecture TMR Indicators He

Strany 16 - SERVICING

MHB44INDOctober2005–Issue25Triguard SC300E MHB44IND Pulse Input and Analogue Output Module ENVIRONMENTAL SPECIFICATIONS The maximum ambient temperatur

Strany 17

6MHB44INDOctober2005–Issue 2Triguard SC300ETECHNICAL DESCRIPTIONPHYSICAL The MHB44IND is a 9U high PCB with integral front panel and rear connectors.

Strany 18

MHB44INDOctober2005–Issue27Triguard SC300E MHB44IND Pulse Input and Analogue Output Module

Strany 19

8MHB44INDOctober2005–Issue 2Triguard SC300EEXTERNAL CONNECTIONS All connections to the MHB44IND are made via DIN 41612 connectors. The upper connector

Strany 20 - SPARE PARTS

MHB44INDOctober2005–Issue29Triguard SC300E MHB44IND Pulse Input and Analogue Output Module THEORY OF OPERATION The module has four isolated 1Hz to 35k

Komentáře k této Příručce

Žádné komentáře