Rockwell-automation 1792D-4BV4D ArmorBlock MaXum 4 Input/4 Output Modu Uživatelský manuál Strana 9

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 16
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 8
ArmorBlock MaXum 4 Input / 4 Output Module with 8 Connectors, Series B 9
Publication 1792D-IN050A-EN-P - February 2001
Troubleshoot with the Indicators
This module has the following indicators:
Network and Module status indicator
Logic status indicator
Auxiliary Power indicator
Individual I/O status indicators for inputs 0 through 3 and
outputs 0 through 3.
The following table describes network and module status indicators.
Net/Mod Status Indicator
Indicator Status
Off No power or auto bauding
Flashing Green/Off On line but not connected
Solid Green On line, link OK, connected
Flashing Red Recoverable fault - module configuration error
I/O connection fault - one or more I/O connections in the timed-out
state
42760
Point indicator for input 0
Module Status
Indicators
Connector A
Connector B
Connector C
Connector D
Connector E
Connector F
Connector G
Connector H
Point indicator for input 1
Point indicator for input 2
Point indicator for input 3
Point indicator for output 3
Point indicator for output 2
Point indicator for output 1
Point indicator for output 0
LED Assignments
Information on connectors
A through H can be found
in the table on page 8.
Zobrazit stránku 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Komentáře k této Příručce

Žádné komentáře