Publication 1756-IN595A-EN-P - March 2004
Installation Instructions
SSI Servo Module
(Catalog Number 1756-M02AS)
The Synchronous Serial Interface (SSI) Servo Module mounts in a
ControlLogix™ chassis and uses a removable terminal block (RTB) to
connect all field-side wiring.
Before you install your module you should have:
installed and grounded a 1756 chassis and power supply.
ordered and received an RTB and its components for your
application.
To: See page:
Note the Power Requirements 4
Identifying Module Components 5
Installing the Module 6
Keying the Module & Removable Terminal Block/Interface Module 7
Wiring a Removable Terminal Block (RTB) 8
Wiring to a Servo Module 10
Wiring Registration Sensors 11
Wiring the Home Limit Switch 12
Wiring the OK Contacts 12
Assembling the Removable Terminal Block and the Housing 13
Installing the Removable Terminal Block onto the Module 13
Checking the LED Indicators 14
Removing the Removable Terminal Block from the Module 19
Removing the Module 20
1756-M02AS Specifications 21
Rockwell Automation Support Back Cover
Zobrazit stránku 0
1 2 3 4 5 6 ... 25 26

Shrnutí obsahu

Strany 1 - SSI Servo Module

Publication 1756-IN595A-EN-P - March 2004Installation InstructionsSSI Servo Module(Catalog Number 1756-M02AS)The Synchronous Serial Interface (SSI) Se

Strany 2 - 2 SSI Servo Module

10 SSI Servo Module Publication 1756-IN595A-EN-P - March 2004Wiring to a Servo ModuleUse the wiring example in the following figure to wire to your

Strany 3 - Environment and Enclosure

SSI Servo Module 11Publication 1756-IN595A-EN-P - March 2004Wiring Registration SensorsThe registration inputs to the servo module can support 24V

Strany 4 - Note the Power Requirements

12 SSI Servo Module Publication 1756-IN595A-EN-P - March 2004Wiring the Home Limit Switch InputThe home limit switch inputs to the servo module are

Strany 5 - Identifying Module Components

SSI Servo Module 13Publication 1756-IN595A-EN-P - March 2004Assembling the Removable Terminal Block and the HousingFigure 11 RTB and HousingInstal

Strany 6 - Installing the Module

14 SSI Servo Module Publication 1756-IN595A-EN-P - March 2004Figure 12 Seating the RTBChecking the LED IndicatorsThe module uses a single bi-colore

Strany 7 - Figure 3 Keying Band

SSI Servo Module 15Publication 1756-IN595A-EN-P - March 2004The table below provides an explanation of the OK indicator.If the OK LED displays:The

Strany 8 - Figure 4 Keying Band

16 SSI Servo Module Publication 1756-IN595A-EN-P - March 2004Module Status Using the FDBK Indicator Figure 14 FDBK Indicator LEDThe table below

Strany 9 - SSI Servo Module 9

SSI Servo Module 17Publication 1756-IN595A-EN-P - March 2004Module Status Using the DRIVE IndicatorFigure 15 Drive Indicator LEDFlashing red light

Strany 10 - Wiring to a Servo Module

18 SSI Servo Module Publication 1756-IN595A-EN-P - March 2004The table below provides an explanation of the DRIVE indicator.If the DRIVE LED displa

Strany 11 - Wiring Registration Sensors

SSI Servo Module 19Publication 1756-IN595A-EN-P - March 2004Removing the Removable Terminal Block from the ModuleIf you must remove the module, yo

Strany 12 - Figure 10 Wiring OK Contacts

2 SSI Servo Module Publication 1756-IN595A-EN-P - March 2004Important User InformationSolid state equipment has operational characteristics differi

Strany 13 - Figure 11 RTB and Housing

20 SSI Servo Module Publication 1756-IN595A-EN-P - March 2004You must remove the RTB before removing the module.Figure 16 Removing the RTBRemoving

Strany 14 - Checking the LED Indicators

SSI Servo Module 21Publication 1756-IN595A-EN-P - March 20041756-M02AS SpecificationsNumber of axes 2 axes maximumServo loopTypeExternal Drive = T

Strany 15 - Publication

22 SSI Servo Module Publication 1756-IN595A-EN-P - March 2004Registration inputsType24V dc input voltageMaximumMinimum onMaximum off5V dc input vol

Strany 16 - Figure 14 FDBK Indicator LED

SSI Servo Module 23Publication 1756-IN595A-EN-P - March 2004Isolation VoltageUser to System 30V continuousRTB keying User-definedField wiring arm3

Strany 17 - Figure 15 Drive Indicator LED

24 SSI Servo Module Publication 1756-IN595A-EN-P - March 2004ESD Immunity IEC 61000-4-2:6kV contact discharges8kV air dischargesRadiated RF Immunit

Strany 18 - 18 SSI Servo Module

SSI Servo Module 25Publication 1756-IN595A-EN-P - March 2004The following information applies when operating this equipment in hazardous locations

Strany 19

Publication 1756-IN595A-EN-P - March 2004 PN 957867-04Copyright © 2004 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.Rockwell Au

Strany 20 - Removing the Module

SSI Servo Module 3Publication 1756-IN595A-EN-P - March 2004Environment and Enclosure Preventing Electrostatic DischargeATTENTIONThis equipment is

Strany 21 - 1756-M02AS Specifications

4 SSI Servo Module Publication 1756-IN595A-EN-P - March 2004Removal and Insertion Under PowerRepeated electrical arcing causes excessive wear to co

Strany 22 - 22 SSI Servo Module

SSI Servo Module 5Publication 1756-IN595A-EN-P - March 2004Identifying Module ComponentsYou received two components with your order:• 1756-M02AS m

Strany 23 - SSI Servo Module 23

6 SSI Servo Module Publication 1756-IN595A-EN-P - March 2004Installing the ModuleYou can install or remove the module while chassis power is applie

Strany 24 - 24 SSI Servo Module

SSI Servo Module 7Publication 1756-IN595A-EN-P - March 20042. Slide the module into the chassis until module tabs ‘click’. Figure 2 Module Locking

Strany 25 - SSI Servo Module 25

8 SSI Servo Module Publication 1756-IN595A-EN-P - March 20042. Push the band until it snaps in place.3. To key the RTB or IFM, insert the wedge-sha

Strany 26 - Rockwell Automation Support

SSI Servo Module 9Publication 1756-IN595A-EN-P - March 2004Connect the wires as shown below.Figure 5 Connecting to Spring Clamp and Cage Clamp RTB

Komentáře k této Příručce

Žádné komentáře