Rockwell-automation 1560E SMC Flex Smart Motor Controller Uživatelský manuál Strana 83

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 198
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 82
Programming 4-3
1560E-UM050B-EN-P - June 2013
Parameter
Motor
Set Up Utility
Linear List
Protection
Parameter
Monitoring
Communications
uw
v
Esc
Parameter
Motor
Set Up Utility
Linear List
Protection
Parameter
Monitoring
Communications
uw
v
EscEsc
Metering
Basic
Overload
Jam
Comm Masks
Language
Linear List
Volts Phase A-B SMC Option Overload Class Jam F Lvl Logic Mask Language All parameters
Volts Phase B-C Motor Connection Service Factor Jam F Dly Parameter Mgt x Parameter Mgt x Parameter Mgt. x
Volts Phase C-A Line Voltage Motor FLC Jam A Lvl
Current Phase A MV Ratio Overload Reset Jam A Dly
Current Phase B Starting Mode Overload A Lvl Parameter Mgt x
Data Links
Motor Data
Current Phase C Ramp Time Parameter Mgt x Data In A1 Motor Flc
Watt Meter Initial Torque Data In A2 Motor ID
Megawatt Hours Cur Limit Lvl
Stall
Data In B1 CT Ratio
Elapsed Time Kickstart Time
Underload
Stall Dly Data In B2 MV Ratio
Meter Reset Kickstart Lvl Underload F Lvl Parameter Mgt x Data In C1 Parameter Mgt x
Power Factor Option 2 Input Underload F Dly Data In C2
Mtr Therm Usage Stop Mode Underload A Lvl Data In D1
Stop Time Underload A Dly
Ground Fault
Data In D2
Braking Current Parameter Mgt x Gnd Flt Enable Data Out A1
Overload Class Gnd Flt Lvl Data Out A2
Service Factor Gnd Flt Dly Data Out B1
Motor FLC
Undervoltage
Gnd Flt Inh Time Data Out B2
CT Ratio Undervolt F Lvl Gnd Flt A Enable Data Out C1
Overload Reset Undervolt F Dly Gnd Flt A Lvl Data Out C2
Aux1 Config Undervolt A Lvl Gnd Flt A Dly Data Out D1
Fault Contact Undervolt A Dly Parameter Mgt x Data Out D2
Alarm Contact Parameter Mgt x Parameter Mgt x
Aux2 Config
Backspin Timer
PTC
Parameter Mgt x
Overvoltage
PTC Enable
Overvolt F Lvl Parameter Mgt x
Dual Ramp (Option 2
Input = Dual Ramp)
Overvolt F Dly
Starting Mode 2 Overvolt A Lvl
Ramp Time 2 Overvolt A Dly
Phase Reversal
Initial Torque 2 Parameter Mgt x Phase Reversal
Cur Limit Lvl 2 Parameter Mgt x
Kickstart Time 2
Kickstart Lvl 2
Parameter Mgt x
Unbalance
Restart
Unbalance F Lvl Starts Per Hour
Preset SS (Option 2 Unbalance F Dly Restart Attempts
Input = Preset SS) Unbalance A Lvl Restart Dly
Slow Speed Sel Unbalance A Dly Parameter Mgt x
Slow Speed Dir Parameter Mgt x
Slow Speed Acc
Slow Running Cur
Parameter Mgt x
(Option 2 Input =
Accu-Stop)
Braking Current
Slow Speed Sel
Slow Speed Dir
Slow Accel Cur
Slow Running Cu
Stopping Current
Parameter Mgt x
Figure 4.2 – Menu Structure Hierarchy
u Depending upon SMC option selected, some parameters may not appear in product display.
v Steps back one level.
w For further information on parameters, see Appendix B.
x For further information on parameter management, see page 4-7.
Zobrazit stránku 82
1 2 ... 78 79 80 81 82 83 84 85 86 87 88 ... 197 198