ICS Regent+PLUS
®
PD
-
7027
Industrial Control Services
1
Monitored Digital Input Modules, Field
Powered (Type F)
24 to 48 VDC, 120 VAC/DC
(T7411F, T7418F)
Issue 1,
March, 06
Monitored digital input modules provide input sensing for 16
field input devices. The field powered (Type F) mod
ules are
suitable for inputs that are directly powered from an external
field power supply. Two types of modules are available for
inputs powered from 24 to 48 VDC and 120 VAC/DC. With a
line monitor device installed at the field switch, monitored
digital input modules detect input switch status and field
wiring open and short circuits (VDC powered inputs only).
Input and line status are reported back to the controller for
use in application program logic.
Features
·
Sixte
en input points, powered from external field supply.
·
Fault tolerant operation when connected in parallel with
another module of the same type.
·
Hot
-
replaceable.
Complete, automatic testing of all input circuits.
Automatic line monitoring detects open and short field wiring
faults.
·
Individual front panel indicators on each m
odule show the
module’s active/fault and power status, as well as input status
and line fault status for each point.
·
2500 volt minimum electrical isolation between field and logic
circuits.
·
TÜV certified, Risk Class 5.
The input module circuits are completely and automatically
tested, providing a fail
-
safe interface for safety
-
critical inputs.
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - ICS Regent+PLUS

ICS Regent+PLUS® PD-7027 Industrial Control Services 1 Monitored Digital Input Modules, Field Powered (Type F) 24 to 48 VDC, 120 VAC/DC (T7411F, T7

Strany 2 - Module Operation

Monitored Digital Input Modules, Type F (T7411F, T7418F) 10 Industrial Control Services Figure 5. Fault Tolerant Monitored Digital Input Mod

Strany 3

Monitored Digital Input Modules, Type F (T7411F, T7418F) PD-7027 Mar-06 11 Line Monitoring For DC powered inputs, the monitored digital input mod

Strany 4

Monitored Digital Input Modules, Type F (T7411F, T7418F) 12 Industrial Control Services Figure 7 shows a single switch connected to a redundant mo

Strany 5

Monitored Digital Input Modules, Type F (T7411F, T7418F) PD-7027 Mar-06 13 With the line monitor device installed, the input voltage, Vin, has fo

Strany 6 - Front Panel Indicators

Monitored Digital Input Modules, Type F (T7411F, T7418F) 14 Industrial Control Services Figure 8. Installing Slot Keys. Table 2. Slot Key Po

Strany 7

Monitored Digital Input Modules, Type F (T7411F, T7418F) PD-7027 Mar-06 15 Configuration Each monitored input module is configured using the WINT

Strany 8 - Application

Monitored Digital Input Modules, Type F (T7411F, T7418F) 16 Industrial Control Services Figure 10. Defining the Input Module Fields and Threshol

Strany 9

Monitored Digital Input Modules, Type F (T7411F, T7418F) PD-7027 Mar-06 17 Line Monitored Input Point dialog, enter names and values for the conf

Strany 10 - Field Wiring

Monitored Digital Input Modules, Type F (T7411F, T7418F) 18 Industrial Control Services Line fault status is only reported through the Fault Name

Strany 11

Monitored Digital Input Modules, Type F (T7411F, T7418F) PD-7027 Mar-06 19 short or open circuit (or there is no line monitor device installed) t

Strany 12 - Industrial Control Services

Monitored Digital Input Modules, Type F (T7411F, T7418F) 2 Industrial Control Services Two or three monitored digital input modules can be connec

Strany 13

Monitored Digital Input Modules, Type F (T7411F, T7418F) 20 Industrial Control Services represent the voted value of the two inputs. This variabl

Strany 14

Monitored Digital Input Modules, Type F (T7411F, T7418F) PD-7027 Mar-06 21 the input module and performing a voted reset, the fault bit is turned

Strany 15

Monitored Digital Input Modules, Type F (T7411F, T7418F) 22 Industrial Control Services For additional safety considerations, please refer to the

Strany 16

Monitored Digital Input Modules, Type F (T7411F, T7418F) PD-7027 Mar-06 23 Input Circuit Test Interval Function of application program scan time

Strany 17

Monitored Digital Input Modules, Type F (T7411F, T7418F) 24 Industrial Control Services Dimensions Height: Width: Depth: 12.6" (320 mm) 1

Strany 18 - Programming

Monitored Digital Input Modules, Type F (T7411F, T7418F) PD-7027 Mar-06 3 monitored input module. The field power is internally regulated to po

Strany 19

Monitored Digital Input Modules, Type F (T7411F, T7418F) 4 Industrial Control Services The bus drivers then move the data onto the I/O Safetybus

Strany 20

Monitored Digital Input Modules, Type F (T7411F, T7418F) PD-7027 Mar-06 5 off failure modes. During testing the D/A converter generates two ref

Strany 21

Monitored Digital Input Modules, Type F (T7411F, T7418F) 6 Industrial Control Services Front Panel Indicators Figure 2 shows the physical feature

Strany 22 - Specifications

Monitored Digital Input Modules, Type F (T7411F, T7418F) PD-7027 Mar-06 7 Figure 2. Type F, Monitored Digital Input Modules.

Strany 23

Monitored Digital Input Modules, Type F (T7411F, T7418F) 8 Industrial Control Services Application Simplex Configuration Monitored digital input

Strany 24

Monitored Digital Input Modules, Type F (T7411F, T7418F) PD-7027 Mar-06 9 Figure 4. Fault Tolerant Monitored Digital Input Modules Connect