Figure 2.8 shows the values that can be displayed on the PMI meter ports. These values are
described in detail in chapter 3. You must enter a Minimum Value and a Maximum Value for each
selection except for those marked as Port Not Used. The Minimum Value is the value at which to
output -1
0V
The Maximum Value is the value at which to output + 1 OV. The system software then
places the units per volt on the screen based on the Minimum/Maximum Values. The Minimum Value
must not be less than -32768. The Maximum Value must not be greater than 32767. The Minimum
Value must be less than the Maximum Value. Note that the PMI meter ports have 8-bit resolution and
are updated on the average every 1 .O millisecond. Refer to the Power Module Interface Rack
instruction manual for more information about the PMI meter ports. Refer to section 3.6.2.1 for
information about resolution of data.
l Port Not Used
l
Armature Current Reference (Counts) (4095 = current limit)
l
Armature Current Feedback (Counts) (4095 = current limit)
l Armature Current Feedback (Amps x 10)
l Armature Voltage (Volts)
l
Armature Maximum Firing Angle
(CL
Sec)
l
Armature Firing Angle
(CL
Sec)
l
Armature Minimum Firing Angle
(p
Sec)
l
Field Current Reference (Counts) (4095 = current limit)
l
Field Current Feedback (Counts) (4095 = current limit)
l Field Current Feedback (Amps x 100)
l Field Voltage (Volts)
l Field Maximum Firing Angle
(CL
Sec)
l
Field Firing Angle
(CL
Sec)
l
Field Minimum Firing Angle
(CL
Sec)
l
Counter EMF Voltage (Volts)
l
A-C RMS Line Voltage (Volts)
l
User Analog Input (Counts) (- 2048 to + 2047 =
+1
-10V)*
l Speed Feedback (RPM)
l Application Data (Units) **
l Rail Port 0 Channel 0 (Counts)
l
Rail Port 0 Channel 1 (Counts)
l
Rail Port 0 Channel 2 (Counts)
l
Rail Port 0 Channel 3 (Counts)
l Rail Port 1 Channel 0 (Counts)
l Rail Port 1 Channel 1 (Counts)
l
Rail Port 1 Channel 2 (Counts)
l Rail Port 1 Channel 3 (Counts)
* Analog input from the Resolver and Drive l/O module. Refer to register
214/1
214 for more information.
**
Refer to register
106/1
106 for more information.
Figure 2.8
-
PMI Meter Port Parameters
-
SD3000
2-11