FACTORYTALK VIEW INSTALLATION GUIDE
120
• • • • •
3. In the FactoryTalk Directory Server Configuration dialog box, click
This computer
,
and then click
OK
.
To change the Network Directory location, you have to log on as an administrator on
the new Network Directory computer (local or remote).
4. Click
OK
, and then restart the client computer.
Install FactoryTalk View SE
1. Close all open Windows programs.
2. Place the FactoryTalk View Installation DVD in the computers DVD drive.
If the DVD does not start automatically, run D:\Setup.exe, where D: is the drive
containing the DVD.
3. Select Site Edition Client and click Next.
Install any necessary product updates
For instructions, see “Installing product updates” on page 132.
Specify Server #2 as the Network Directory location
After upgrading the software on the client computer, specify Server #2 as the Network
Directory location.
1. On the client computer, click Start > All Programs > Rockwell Software >
FactoryTalk Tools, and then click
Specify FactoryTalk Directory Location
.
To use the FactoryTalk Directory Server Location Utility, you have to log on as an
administrator on the local computer.
2.
Localhost
should be displayed in the field, Computer hosting directory server. Click
the Browse button.
3. In the FactoryTalk Directory Server Configuration dialog box, type
Server #2
, and
then click
OK
.
To change the Network Directory location, you have to log on as an administrator on
the new Network Directory computer (local or remote).
4. Click
OK
, and then restart the client computer.
FTViewSEInstallENU.book Page 120 Wednesday, July 16, 2014 10:53 AM