RSLogix 5000 Code Examples Chapter 9
Example Routine
In the example routine below, the initialization in Rung 1 sets the address, length,
data, and command. Because the address, length and Data[0] can only be 0, the
source in the MOV instruction can be set to 0. The UIDLow, UIDHi, BlockSize,
Reset and Timeout are set to 0 in the output image table.
Example Results
The following information will be displayed:
xx:I.Channel[0].Data[0…1] = Device ID
xx:I.Channel[0].Data[2…5] = Baud rate
xx:I.Channel[0].Data[6…7] = Retry setting
xx:I.Channel[0].Data[8…9] = Gain
Gain is 0…3, with 0 being the highest gain.