CIP Information Appendix B
Writing to the Output Image
Table of a 56RF-IN-IPD22
with a MicroLogix 1400
N20:0 is the data table address to store the output image and will span
N20:0…N20:61.
The number of bytes to send is 124 (62 words).
The extended routing file (RIX12:0) is used to store the Multi-Hop
routing information.
Service is type Write Assembly
Class 4 is the Assembly Instance Class
Instance 83h is the output image connection instance.
Attribute 3 is the assembly attribute for the output image table
The Multi-Hop information is used to configure the communications path from
the MicroLogix to the RFID interface.