The allocation of pins on the I/O extension PCB is described
below.
Table 13: J14 Pin Listings
LED Indicators
The following table describes LED statuses for LED’s D10 through
D14 present on the I/O extension PCB.
Table 14: I/O Board LED Descriptions
DIP Switch Settings
DIP switches 1 through 6 on the S1 DIP switch array are
configured for the various applications described below. If no
information is otherwise provided these DIP switches should
remain in the OFF position.
DIP switch 7 is used to configure the overhang mode (see user
manual for further information) and DIP switch 8 is used to reset
default configuration. Note that once changed, DIP switch
settings are only recognized after a power cycle.
Table 15 details DIP switch settings for the I/O board. Please refer
to the Programming Guide for further information on the listed
functions.
Pin Signal 0V DC +24V DC
1 Out 3 Zone Z1 interrupted Zone Z1 not interrupted
2 Out 4 Zone Z2 interrupted Zone Z2 not interrupted
3 Out 5 Zone Z3 interrupted Zone Z3 not interrupted
4 Out 6 Zone Z4 interrupted Zone Z4 not interrupted
LED Description Status Meaning
D10 Zone 1
Off Out 3 = OFF (0 VDC)
Green Out 3 = ON (24 VDC)
D11 Zone 2
Off Out 4 = OFF (0 VDC)
Green Out 4 = ON (24 VDC)
D12 Zone 3
Off Out 5 = OFF (0 VDC)
Green Out 5 = ON (24 VDC)
D13 Zone 4
Off Out 6 = OFF (0 VDC)
Green Out 6 = ON (24 VDC)
D14 Teach
Off Teach inactive
Flashing Teach in progress
Orange Last teach step
Table 15: I/O Board DIP Switch Settings
Default Parameters
Table 9 lists the default values for each of the parameters
discussed above, that can be reset by use of switch 8 on DIP
switch array S1, followed by a power cycle.
Table 16: Default Parameters for I/O Model
Teach Process
The teach function allows the user to configure the parameters for
a number of functions by use of a push button on the I/O
extension PCB. The following sections detail the parameters that
can be taught to the sensor, as well as the steps associated with
this procedure.
Function
DIP Switch S1 (O: OFF, 1: ON, X: not relevant)
87654321
Default setting 00000000
Standard beam counting direction 0X0X0000
Reverse beam counting direction 0X1X0000
Output logic (default)
active low
XXX0XXX
Output logic active high XXX1XXX
Overhang monitoring
with time delay
00XX0000
Overhang monitoring with trigger
sensor
01XX0000
Set Default 1XXXXXXX
Parameter Default value (beam no.)
zc – Carrier zone 1 1
oh – Over-height 1 1
z1L – Zone 1 Lowest beam 1 1
z1H – Zone 1 Highest beam n/4 n/4
z2L – Zone 2 Lowest beam z1H+1 z1H+1
z2H – Zone 2 Highest beam 2n/4 2n/4
z3L – Zone 3 Lowest beam z2H+1 z2H+1
z3H – Zone 3 Highest beam 3n/4 3n/4
z4L – Zone 4 Lowest beam z3H+1 z3H+1
z4H – Zone 4 Highest beam n n
Beam counting mode 0 = first beam cable side
n = total number of beams in the light array
ATTENTION
Protect the controller from ESD with proper
grounding or shunting and the use of static
control packaging and materials handling
products. Dissipate and neutralize by
grounding, ionization, and the use of
conductive and dissipative static control
materials.