Installation Instructions
PowerFlex
®
DC Drive - Frame B Field SCR
Module
What This Kit Includes
Field SCR module
Two screws and washers
Two gate leads
Thermal grease
Static strap
Important:It is highly recommended that the Field circuit board and Field
Dual Diode module be replaced when replacing the Field SCR
module. The Field circuit board and Field Dual Diode module
are sold as separate spare part kits.
Tools That You Need
Phillips
®
screwdriver
Flathead screwdriver
Phillips
®
is a registered trademark of Phillips Screw Company.
ATTENTION: Only qualified personnel familiar with DC
drives and associated machinery should plan or implement the
installation, start-up and subsequent maintenance of the system.
Failure to comply may result in personal injury and/or equipment
damage.
ATTENTION: To avoid an electric shock hazard, ensure that all
power to the drive has been removed before performing the
following.
ATTENTION: This drive contains ESD (Electrostatic
Discharge) sensitive parts and assemblies. Static control
precautions are required when installing, testing, servicing or
repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with
static control procedures, reference A-B publication 8000-4.5.2,
“Guarding Against Electrostatic Damage” or any other
applicable ESD protection handbook.
Zobrazit stránku 0
1 2 3 4 5 6 ... 13 14

Shrnutí obsahu

Strany 1 - PowerFlex

Installation InstructionsPowerFlex® DC Drive - Frame B Field SCR Module What This Kit Includes• Field SCR module• Two screws and washers• Two gate lea

Strany 2 - What You Need to Do

10 PowerFlex® DC Drive - Frame B Field SCR Module12. Remove the appropriate gate leads:– For non-regenerative drives, remove each pair of (orange and

Strany 3 - Step 1: Remove Power

PowerFlex® DC Drive - Frame B Field SCR Module 1113. Remove the seven screws that secure the Pulse Transformer and Switching Power Supply boards to th

Strany 4 - Protective Covers

12 PowerFlex® DC Drive - Frame B Field SCR ModuleStep 4: Remove the Field Board and Existing Field SCR Module1. Remove the wires from connectors UF, U

Strany 5 - Power Supply Boards

PowerFlex® DC Drive - Frame B Field SCR Module 13Step 5: Install the Field Board and New Field SCR ModuleInstall the Field board and new Field SCR mod

Strany 6 - Remove connector from XCD_IO

Publication 20P-IN045B-EN-P - December 2009Supersedes 20P-IN045A-EN-P - March 2009 Copyright © 2009 Rockwell Automation. All rights reserved. Printed

Strany 7

2 PowerFlex® DC Drive - Frame B Field SCR ModuleWhat You Need to DoThe Field SCR module is located below the Field board, which is below the Control b

Strany 8 - Transformer board

PowerFlex® DC Drive - Frame B Field SCR Module 3Step 1: Remove Power from the Drive1. Remove and lock-out all incoming power to the drive. ATTENTION:

Strany 9 - Remove ground

4 PowerFlex® DC Drive - Frame B Field SCR ModuleStep 2: Remove the Protective Covers1. Disconnect the DPI cable from the HIM assembly (if present).2.

Strany 10

PowerFlex® DC Drive - Frame B Field SCR Module 54. Disconnect the HIM Communication cable from the connector on the upper right corner of the Control

Strany 11 - Remove screws

6 PowerFlex® DC Drive - Frame B Field SCR Module3. Remove the cable from connector XTA on the Pulse Transformer board.4. Remove the plug-in terminals

Strany 12 - SCR Module

PowerFlex® DC Drive - Frame B Field SCR Module 76. Carefully disconnect the cables from connectors XA, XR and XFCD at the top of the Control board. 7.

Strany 13

8 PowerFlex® DC Drive - Frame B Field SCR Module9. Remove the cable from connector XV on the Switching Power Supply board.10. Remove the cables from c

Strany 14 - Related Documentation

PowerFlex® DC Drive - Frame B Field SCR Module 911. Remove the ground connection at the left side of the Pulse Transformer board. Remove ground connec

Komentáře k této Příručce

Žádné komentáře