Publication 999-126 - February 1996
Installation & Hook-Up 17
Figure 2.6
Terminal diagram
2.
3. Using a small, flat-head screwdriver, turn the clamping screw
counter-clockwise several times.
4. Using a proper stripping tool, strip the wire insulation back on the
cable lead.
Important: All terminals accommodate a maximum of 14 gauge
wire.
5. Trim the cable lead so that 0.275 inches of metal wire is exposed.
6. Insert the cable lead in the appropriate terminal. Refer to the
proper figures for their locations.
7. Use the screwdriver to tighten the clamping screw to the proper
torque (0.25 N-m/2.2 in-lb.).
8. Verify that the cable lead does not pull out of the terminal.
9.
Terminal open
Terminal closed
Clamping screws
Table 1: Terminal Steps
If the terminals are: Do this:
Not open Go to step 3
Open Go to step 4
Table 2: Cable Leads
If the cable lead: Do this:
Pulls out of the terminal Repeat steps 3 through 9 again
Does not pull out of the terminal Repeat steps 3 through 9 for the next
terminal