Rockwell-automation 4100 ESRS Encoder Signal Reference Simulator Insta Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Rockwell-automation 4100 ESRS Encoder Signal Reference Simulator Insta. Rockwell Automation 4100 ESRS Encoder Signal Reference Simulator Installation Manual User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Simulator

ESRS – Encoder Signal Reference Simulator(Cat. No. 4100-ESRS)Installation and Setup Manual

Strany 2 - Important User Information

Publication 4100-IN505A-EN-P - October 2000 Preface P-4For specific definitions of other terms used in industrial automation, see the Allen-Bra

Strany 3 - Directive Compliance

Publication 4100-IN505A-EN-P - October 2000 Preface P-5Leave the product in its shipping container prior to installation. If you are not going

Strany 4

Publication 4100-IN505A-EN-P - October 2000 Preface P-6The Rockwell Automation Technical Support numbers are:in Europe: (+44) 1270 580142in Nor

Strany 5 - Chapter 2

1 Publication 4100-IN505A-EN-P - October 2000 Chapter 1OverviewESRS DescriptionThe Encoder Signal Reference Simulator (ESRS) generates a digital speed

Strany 6 - Chapter 3

Publication 4100-IN505A-EN-P - October 2000 1-2 Overview•Digital output indicates phase of quadrature pulse train (i.e. direction of motor rota

Strany 7 - Purpose of this Manual

Publication 4100-IN505A-EN-P - October 2000 Overview 1-3ESRS FootprintThe following figure shows the footprint of the ESRS with fixing hole dim

Strany 8 - Safety Precautions

Publication 4100-IN505A-EN-P - October 2000 1-4 OverviewESRS Principal SpecificationsMechanical SpecificationsEnvironmental SpecificationsPower

Strany 9 - Terminology

Publication 4100-IN505A-EN-P - October 2000 Overview 1-5Quadrature OutputIndex PulseI/O FilteringTable 1.D Quadrature OutputNumber of quadratur

Strany 10 - Storage Responsibility

Publication 4100-IN505A-EN-P - October 2000 1-6 Overview

Strany 11 - Allen-Bradley Support

1 Publication 4100-IN505A-EN-P - October 2000 Chapter 2InstallationThe ESRS is designed to be mounted in an electrical cabinet via the mounting tabs o

Strany 12 - On the Web

Important User InformationBecause of the variety of uses for the products described in this publication, those responsible for the application and use

Strany 13 - Overview

Publication 4100-IN505A-EN-P - October 2000 2-2 InstallationMounting the ESRSThe ESRS must be properly grounded to the metal enclosure panel. T

Strany 14 - ESRS Front Panel

Publication 4100-IN505A-EN-P - October 2000 Installation 2-3Figure 2.2 ESRS Continually Enabled – Power Supplied by the ESRS

Strany 15 - ESRS Footprint

Publication 4100-IN505A-EN-P - October 2000 2-4 InstallationThe next diagram shows how to connect the ESRS to enable the device from a source p

Strany 16 - Power Supply and Fuses

Publication 4100-IN505A-EN-P - October 2000 Installation 2-5This figure shows how to connect the ESRS to enable the device from its internal En

Strany 17 - I/O Filtering

Publication 4100-IN505A-EN-P - October 2000 2-6 InstallationThis diagram shows how to connect the ESRS to enable the device from a source provi

Strany 18 - 1-6 Overview

Publication 4100-IN505A-EN-P - October 2000 Installation 2-7recommended minimum current capacity for the external power supply is 1 Amp.This di

Strany 19 - Installation

Publication 4100-IN505A-EN-P - October 2000 2-8 InstallationThe next diagram shows the ESRS connected to a power supply adjacent to the drive o

Strany 20 - Enable Input

1 Publication 4100-IN505A-EN-P - October 2000 Chapter 3OperationGeneralYour ESRS is fitted with a range of indicators and controls to allow easy confi

Strany 21 - Installation 2-3

Publication 4100-IN505A-EN-P - October 2000 3-2 OperationWhen Set To Bi-directional When Bi-directional Mode is selected, zero speed occurs at

Strany 22 - 2-4 Installation

Publication 4100-IN505A-EN-P - October 2000 Operation 3-3EXT – This setting selects a customer supplied line speed input via the EXT LINE SPEED

Strany 23 - Installation 2-5

European Communities (EC) Directive ComplianceIf this product has the CE mark it is approved for installation within the European Union and EEA region

Strany 24 - External Power Supply

Publication 4100-IN505A-EN-P - October 2000 3-4 OperationThe Strobe Out is a square wave. Its falling edge is centered between the consecutive

Strany 25 - Installation 2-7

Publication 4100-IN505A-EN-P - October 2000 Operation 3-5The following table shows the Pin number and its signal name.Enable VoltageThis provid

Strany 26 - 2-8 Installation

Publication 4100-IN505A-EN-P - October 2000 3-6 OperationP2The P2 connector is a 15 way male high density D connector. It allows you to make co

Strany 27 - Operation

Publication 4100-IN505A-EN-P - October 2000 Operation 3-7Setting the Option SwitchYou must remove the side panel of the ESRS box to gain access

Strany 28 - Line Selection

Publication 4100-IN505A-EN-P - October 2000 3-8 OperationIndex Division Ratio SelectionSwitch 3 and Switch 4 are used to create 4 patterns base

Strany 29 - Inputs and Outputs

Publication 4100-IN505A-EN-P - October 2000 IndexAAllen-Bradley Support P-5CCommon Techniques P-4Connectingexternal power supply 2-6External Power Sup

Strany 30 - Ext Line Speed In

Publication 4100-IN505A-EN-P - October 2000 I-2 Indextechnical product assistance, P-5supportOn the Web P-6TTerminology P-3WWho Should Use this

Strany 31 - Direction Output

Publication 4100-IN505A-EN-P - October 2000 1 PN 4100-IN505ASupersedes Publication 4100-5.5 - November 1998 © 2000 Rockwell International Corporation.

Strany 33 - Setting the Option Switch

i Publication 4100-IN505A-EN-P - October 2000 Table of ContentsPrefaceUsing This ManualRead This Manual . . . . . . . . . . . . . . . . . . . . . . .

Strany 34 - Maximum Effective Motor Speed

Publication 4100-IN505A-EN-P - October 2000 iiChapter 3OperationGeneral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 35

1 Publication 4100-IN505A-EN-P - October 2000 PrefaceRead This ManualRead and understand this instruction manual. It provides the necessary informatio

Strany 36 - I-2 Index

Publication 4100-IN505A-EN-P - October 2000 Preface P-2Safety PrecautionsThe following general precautions apply to the Encoder Signal Referenc

Strany 37 - Back Cover

Publication 4100-IN505A-EN-P - October 2000 Preface P-3Contents of this ManualRelated DocumentationThe following documents contain additional i

Komentáře k této Příručce