Adapter Parameters B-5
35 PIDD W7 Actual
Actual Process Input Data Description for Word 7.
Value: See Ta b l e B . 1
Type: Read Only
36 PIDD W8 Cfg
Configured Process Input Data Description for
Word 8. PCP Object to use for Word 8 transmitted
to Interbus master.
Default: 0
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
37 PIDD W8 Actual
Actual Process Input Data Description for Word 8.
Value: See Ta b l e B. 1
Type: Read Only
38 PODD W0 Cfg
Configured Process Output Data Description for
Word 0. PCP Object to use for Word 0 received
from Interbus master.
Default: 0x2F98
(Logic Command)
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
39 PODD W0 Actual
Actual Process Output Data Description for Word
0.
Value: See Ta b l e B. 1
Type: Read Only
40 PODD W1 Cfg
Configured Process Output Data Description for
Word 1. PCP Object to use for Word 1 received
from Interbus master.
Default: 0x2F99
(Reference)
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
41 PODD W1 Actual
Actual Process Output Data Description for Word
1.
Value: See Ta b l e B. 1
Type: Read Only
42 PODD W2 Cfg
Configured Process Output Data Description for
Word 2. PCP Object to use for Word 2 received
from Interbus master.
Default: 0
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
43 PODD W2 Actual
Actual Process Output Data Description for Word
2.
Value: See Ta b l e B. 1
Type: Read Only
44 PODD W3 Cfg
Configured Process Output Data Description for
Word 3. PCP Object to use for Word 3 received
from Interbus master.
Default: 0
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
45 PODD W3 Actual
Actual Process Output Data Description for Word
3.
Value: See Ta b l e B. 1
Type: Read Only
46 PODD W4 Cfg
Configured Process Output Data Description for
Word 4. PCP Object to use for Word 4 received
from Interbus master.
Default: 0
Setting: See Ta b l e B . 1
Type: Read/Write
Reset Required: No (becomes active
when Interbus network
is restarted)
Parameter
No. Name and Description Details
20COMM-UM007A-EN-P.book Page 5 Tuesday, January 22, 2002 10:52 AM