Rockwell-automation 1794-ID2 U.MNL INCREMENTAL ENCODER Uživatelský manuál Strana 77

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 88
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 76
7–3Calibrating Your Incremental Encoder Module
(! ' #" *  ) 
Calibration Method 2
Calibration is enabled by input G if GateControl = 3 and Calibrated
= 0. The preset value is copied to the counter register at a positive
edge on input signal Z. The old counter register value is saved in the
store register for evalution.
Calibration direction is determined by CalDirection (0 = positive
direction, 1 = negative direction).
Reset Calibrated, Stored and PresetReached after calibration with
CalReset, StoreReset and PresetReset.
#("'%  &'%
'#%  &'%
#("'%  &'%
# 
%&'  &'%
PresetReached = 1
Stored = 1
CalDirection =  %' #"
# ' !'&' #("' $(!&
Calibrated = 0
StoreControl = 0
Stored = 0
Calibrated = 1
# 

GateControl = 3
Zobrazit stránku 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 87 88

Komentáře k této Příručce

Žádné komentáře