RTD Input Module 7
Publication
1771-5.50 – October 1996
Use the configuration information below to configure your module
to your specifications.
Dec. Bits 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
De o
Octal Bits 17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00
De
scripti
o
n
Word
1
Real T
ime Sampling -
default = no R
TS
Data
Format
RTD
Type
Units of
Measure
Single channel in ohms
Real time sampling, data format, R
TD
type units of measure, and single
channel in ohms
3.1s
In temperature mode:
0 = Entire module is platinum
1 = Entire module is 10 ohm copper.
Enter exact value in word 2.
In ohms mode:
0 = 30mohm/count resolution
1 = 10mohm/count resolution
If any of these bits are set, the corresponding input
channel will be reported in ohms. If RTDs other than 10
ohm copper or 100 ohm platinum are used you must
report those channels in ohms, not degrees. Data format
on a channel displayed in ohms will default to binary.
Determines what units of measure
the module reports.
Units of measure
Bit 07 Bit 06
Degrees C
Degrees F
Ohms
Not used
00
01
10
11
Set to match your
processor.
BCD (default)
Reserved
Two’s complement binary
Signed magnitude binary
Bit 10 Bit 09
0
0
1
1
0
1
0
1
0.5s
0.4s
0.3s
0.2s
0.1s
1.0s
0.6s
0.7s
0.8s
0.9s
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
1
1
1
0
0
0
0
0
1
1
0
0
1
1
1
0
1
0
1
0
0
0
0
0
0
0
0
1
1
1
1
0
1
1
1
0
0
0
0
1
1
0
0
1
0
1
1
1
000 01
1.5s
2.0s
2.5s
3.0s
0
00
1
1
0
1
1
1
111
No RTS (50ms)
Important: Use decimally addressed bit
locations for PLC-5 processors.
2
If
bit 10 is set in word 1, and temperature readings are desired, word 2 must also be used. Enter
the exact resistance of 10 ohm RTD at 25
o
C in BCD. Range is 9.00 to 1
1.00 ohms. V
alues less
than 9.00 ohms or greater than 1
1.00 ohms will default to 10.00 ohms. Non–BCD values will also
default to 10.00 ohms.
10 ohm resistance @ 25
_C
3, 4, 5, 6, 7, 8
Individual channel bias
- entered in BCD. This value is subtracted from the channel data in the
BTR. The bias value is always a positive number. Bias value range is 0<
bias<9999.
Channel 1-6 bias
9, 10, 11, 12, 13,
14, 15
Channel 1-6 calibration
Individual channel calibration
15
Not used
Channel failed calibration
FC EE
Not used
S G O
auto-calibration request word
Offset calibration complete
Gain calibration complete
Save complete
EEPROM fault
Faulty calibration (no save)
For detailed configuration
information, see chapter 5 of your
RTD Input Module User Manual
(publication 1771-6.5.76).
Configure the Module