Compact 1769-OF4CI Isolated Analog Output Module 25
Rockwell Automation Publication 1769-IN075B-EN-P - August 2010
Hazardous Location Considerations
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or
non-hazardous locations only. The following ATTENTION statement applies
to use in hazardous locations.
Specification 1769-OF4CI
System Power Supply Distance Rating The module may not be more than 8 modules
away from the system power supply.
Recommended Cable Belden 8761 (shielded)
Vendor I.D. Code 1
Product Type Code 10
Product Code 45
Input Words 6
Output Words 5
Configuration Words 32
WARNING: EXPLOSION HAZARD
Substitution of components may impair suitability for Class I,
Division 2.
When in hazardous locations, turn off power before wiring or
replacing modules.
Do not disconnect equipment unless power has been switched off
or the area is known to be non-hazardous.
This product must be installed in an enclosure.
All wiring must comply with N.E.C. article 501-4(b).