Rockwell-automation 1769-ASCII Compact Module Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Rockwell-automation 1769-ASCII Compact Module. Rockwell Automation 1769-ASCII Compact Module User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 40
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Publication 1769-IN068B-EN-P - May 2005
Installation Instructions
Compact 1769-ASCII Module
Cat. No. 1769-ASCII
Inside…
About the Module ............................................................................................4
Install the Module
.............................................................................................5
Assemble the System
........................................................................................6
Mount Expansion I/O
....................................................................................8
Ground the Module
........................................................................................12
Connect the D-sub Connector Pins
............................................................13
I/O Memory Mapping
...................................................................................16
Configure the 1769-ASCII Module
.............................................................25
Specifications
...................................................................................................29
Status Indicators
..............................................................................................32
Troubleshoot with Error Codes
...................................................................33
Zobrazit stránku 0
1 2 3 4 5 6 ... 39 40

Shrnutí obsahu

Strany 1 - Compact 1769-ASCII Module

Publication 1769-IN068B-EN-P - May 2005Installation InstructionsCompact 1769-ASCII ModuleCat. No. 1769-ASCIIInside…About the Module ...

Strany 2 - Important User Information

10 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 20055. Place the modules back on the panel, and check for proper hole alignment.6.

Strany 3

Compact 1769-ASCII Module 11Publication 1769-IN068B-EN-P - May 2005Replace a Single Module Within a SystemThe module can be replaced while the sys

Strany 4 - About the Module

12 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 20056. Before installing the replacement module, be sure that the bus lever on the

Strany 5 - Install the Module

Compact 1769-ASCII Module 13Publication 1769-IN068B-EN-P - May 2005Connect the D-sub Connector PinsAll pins are active at all times.IMPORTANTPins

Strany 6 - Assemble the System

14 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005Figure 1 RS-232 Wiring Diagram - Module to DTE Device (Hardware Handshaking Dis

Strany 7

Compact 1769-ASCII Module 15Publication 1769-IN068B-EN-P - May 2005Figure 3 RS-422 Wiring Diagram Figure 4 RS-485 Wiring DiagramTXD-NCNC1234COM5RX

Strany 8 - Mount Expansion I/O

16 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005I/O Memory MappingThe 1769-ASCII module supports an input assembly that is acce

Strany 9 - Panel Mount

Compact 1769-ASCII Module 17Publication 1769-IN068B-EN-P - May 2005• CNO = Channel number of the output data being sent. This bit is set by the PL

Strany 10 - Mount on the DIN Rail

18 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005• NR = Non-delimited record. An input record is received and sent to the Compac

Strany 11 - 1769-IN068B-EN-P - May 2005

Compact 1769-ASCII Module 19Publication 1769-IN068B-EN-P - May 2005Simultaneous Mode (Two Channels) Input FileMaximum size is shown below. Refer t

Strany 12 - Ground the Module

2 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005Important User InformationBecause of the variety of uses for the products descri

Strany 13 - IMPORTANT

20 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005• TS = Transmit sent. Indicates the ASCII module has sent the data indicated by

Strany 14 - ASCII DTE DTE 9-pin 25-pin

Compact 1769-ASCII Module 21Publication 1769-IN068B-EN-P - May 2005Simultaneous Mode (Two Channels) Output FileMaximum size is shown below. Refer

Strany 15

22 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005Configuration FileThe 1769-ASCII module supports a configuration assembly that

Strany 16 - I/O Memory Mapping

Compact 1769-ASCII Module 23Publication 1769-IN068B-EN-P - May 2005Module Production Data8Pad Character(1)0…127/255 0…0x7f (0…127) for 7-bit data

Strany 17

24 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005Serial Port Receive Data18 Max Number of Receive Characters0…200 In Simultaneou

Strany 18 - 1769-IN068B-EN-P - May 2005

Compact 1769-ASCII Module 25Publication 1769-IN068B-EN-P - May 2005Configure the 1769-ASCII ModuleEnter the configuration data for your 1769-ASCII

Strany 19

26 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 20052. Enter the appropriate values as listed below.3. Choose OK.4. From the Generi

Strany 20

Compact 1769-ASCII Module 27Publication 1769-IN068B-EN-P - May 2005Configure with RSLogix 5000 Software1. Right-click on the 1769-ASCII module and

Strany 21

28 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 20055. Double-click on the controller tags.6. Enter your configuration data.Refer t

Strany 22 - Configuration File

Compact 1769-ASCII Module 29Publication 1769-IN068B-EN-P - May 2005SpecificationsVendor I.D. Code 1Product Type Code 109Product Code 66Input Words

Strany 23

Compact 1769-ASCII Module 3Publication 1769-IN068B-EN-P - May 2005IMPORTANTIdentifies information that is critical for successful application and

Strany 24

30 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005General SpecificationsEnvironmental ConditionsOperational Temperature IEC 60068

Strany 25

Compact 1769-ASCII Module 31Publication 1769-IN068B-EN-P - May 2005Conducted RF Immunity IEC 61000-4-6: 10 Vrms with 1 kHz sine-wave 80% AM from 1

Strany 26

32 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005Status IndicatorsThe following table defines the ASCII module status indicators

Strany 27 - Maximum size listed

Compact 1769-ASCII Module 33Publication 1769-IN068B-EN-P - May 2005Troubleshoot with Error CodesConfiguration Error CodesValue (Hex) Meaning0 No e

Strany 28

34 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005Channel 0 Module Errors430 Data buffer mode 0 = alternate mode; 1 = simultaneou

Strany 29 - Specifications

Compact 1769-ASCII Module 35Publication 1769-IN068B-EN-P - May 200544E Invalid transmit swap mode The transmit swap mode specified is invalid.44F-

Strany 30

36 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 200548C Invalid transmit record end mode The transmit record end mode specified is

Strany 31

Compact 1769-ASCII Module 37Publication 1769-IN068B-EN-P - May 2005North American Hazardous Location ApprovalThe following information applies whe

Strany 32 - Status Indicators

38 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005Compact and RSLogix are trademarks of Rockwell Automation, Inc.Trademarks not b

Strany 33 - Troubleshoot with Error Codes

Compact 1769-ASCII Module 39Publication 1769-IN068B-EN-P - May 2005Notes:

Strany 34

4 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005About the ModuleThe 1769-ASCII module provides a flexible network interface to a

Strany 35

Publication 1769-IN068B-EN-P - May 2005 PN 957955-78Supersedes Publication 1769-IN068A-EN-P - Ma

Strany 36

Compact 1769-ASCII Module 5Publication 1769-IN068B-EN-P - May 2005Install the ModuleCompact I/O is suitable for use in an industrial environment w

Strany 37

6 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 2005Assemble the SystemAttach the module to the controller or an adjacent I/O module

Strany 38

Compact 1769-ASCII Module 7Publication 1769-IN068B-EN-P - May 20051. Disconnect power.2. Check that the bus lever of the module to be installed is

Strany 39

8 Compact 1769-ASCII Module Publication 1769-IN068B-EN-P - May 20057. Attach an end-cap terminator (5) to the last module in the system by using th

Strany 40 - Rockwell Automation Support

Compact 1769-ASCII Module 9Publication 1769-IN068B-EN-P - May 2005Panel MountMount the module to a panel by using two screws per module. Use M4 or

Komentáře k této Příručce

Žádné komentáře