Publication 1734-UM007D-EN-P - December 2005
A-4 Configure Modules in RSLogix 5000 Software
For more information on these parameters refer to the definitions in
Chapter 4 of this publication.
Work with the Conversion
Dialog
Follow these procedures to complete entries for the Conversion
dialog.
1. From the General dialog, click Conversion to display the
Conversion dialog.
2. From the Conversion dialog, complete entries, referring to the
table.
For Select Comments
Code Type Binary or Gray Default is Gray.
Word Length 2…31 Default is 13.
Data Speed 125 Kbps
250 Kbps
500 Kbps
1 MBps
2 MBps
Default is 125 Kbps.
SSI Word Delay
Time
16…65535 Default is 64 µs.
SSI Word Filter
Control
Max
High
Med
Low
Off
Default is Max.
SSI Clock Select On or Off to select the SSI clock.