Rockwell-automation 1440-DYN02-01RJ XM Dynamic Measurement Module Uživatelský manuál Strana 14

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 20
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 13
14 XM Dynamic Measurement Module
Publication
ICM-IN002A-EN-P - March 2009
Network Status (NS) Off Module is not online.
Module is autobauding.
No power applied to the module;
look at Module Status LED.
Flashing Red One or more I/O connections are in the
timed-out state.
Solid Red Failed communications (duplicate MAC ID
or bus-off).
Flashing Green Module is online but no connections are
currently established.
Solid Green Module is online with connections
currently established.
Channel 0 &
Channel 1
Off Normal operation within alarm limits
on the channel.
No power applied to the module; look
at the Module Status LED.
Solid Yellow Alarm associated with this channel is in
Alert.
Solid Red Alarm associated with this channel is in
Danger.
Flashing Red A transducer fault exists on the channel.
DC bias is outside the DC Low and High
Limits.
Tachometer Off Normal operation within alarm limits
on the channel.
No power applied to the module; look
at the Module Status LED.
Solid Yellow Alarm on Speed or Acceleration is in
Alert.
Solid Red Alarm on Speed or Acceleration is in
Danger.
Indicator State Description