Interconnect Diagrams B-17
The example below shows 1394 Series B axis modules without
internal brake filtering. Any axis connected to a motor with a brake
requires a separate pilot relay for noise isolation.
Figure B.15
Isolated Brake (with pilot relay) Interconnect Diagram
Note: Refer to Figure 2.8 for the location of the TB1/TB2 connectors
and pin-out diagram.
Note: Refer to figures 2.1 and 2.2 for the location of the 10-pin relay
output connector.
CR6
24V DC
Power Supply
+ DC
DC com
CR6
10
9
Relay
Output 0
CR7
CR7
8
7
Relay
Output 1
CR8
CR8
6
5
Relay
Output 2
CR9
CR9
43
Relay
Output 3
1394 SERCOS Interface Control Board 1394C-SJT
xx
-D
TB1
TB2
1394-AM
xx
Axis 0 Axis 1 Axis 2 Axis 3
TB1
TB2
1394-AM
xx
TB1
TB2
1394-AM
xx
TB1
TB2
1394-AM
xx
1 2
3 4
Motor Brake
1 2 3 4
1 2 3 4
1 2
3 4
1 2 3 4
1 2
3 4
1 2
1 2 3 4
1 2
3 4
1 2
1 2
1 2
Zobrazit stránku 132