2-6 Installation
characteristic of the particular inductive device. See the table on page 2-7 for
recommended suppressors.
For inductive dc load devices, a diode is suitable. A 1N4004 diode is acceptable for
most applications. A surge suppressor can also be used. See the table on page 2-7
for recommended suppressors.
As shown in the illustration below, these surge suppression circuits connect directly
across the load device.
Surge Suppression for Inductive ac Load Devices
Output Device
Output Device
Output Device
Varistor RC Network Surge
Suppressor
Surge Suppression for Inductive dc Load Devices
Output Device
Diode
_
+
(A surge suppressor can also be used.)