PD-T8030S
Issue 23 April 10 PD-T8030S 1
Trusted
TM
OPC Server Package
Introduction
The OPC Server Package is a Windows based software application that allows OPC compatible clients
to connect to a Trusted
T
M
System and access the process data.
This document describes the OPC server in its Windows Service form (T8030S). For OPC Server
release 17 and earlier and other executable versions (T8030X), please refer to issue 14 of this
document.
Features
Industry standard OPC interface
Supports OPC Data Access v1.0, v2.05a and OPC Alarms & Events v1.1
Single or Dual-redundant link to a Trusted
TM
System
Handles up to 32 Trusted
TM
Controllers
Update rate of down to 10ms.
Events time-stamped to a resolution of 1ms
Collects sequence of events ( SOE ) and process historian data
Automatically interfaces to IEC1131 TOOLSET to obtain tag references in Trusted
TM
Controllers
Online monitoring of tag values
Reports communications and server status to Clients
Operates as a Windows Service regardless of user login (T8030S)
Zobrazit stránku 0
1 2 3 4 5 6 ... 48 49

Shrnutí obsahu

Strany 1 - OPC Server Package

TrustedTM PD-T8030S Issue 23 April 10 PD-T8030S 1 TrustedTM OPC Server Package Introduction The OPC Server Package is a Windows based software appl

Strany 2

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 10 Revision and Updating Policy All new and revised information pertinent to this document shall be

Strany 3

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 11 1. Description 1.1. Overview OPC (OLE for Process Control ) is an industry standard for transfer

Strany 4

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 12 TrustedTM Ethernet IF Controller # 1 Controller # 2 1.2. TrustedTM OPC Architecture The server c

Strany 5 - Table of Contents

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 13 1.2.4. OPC Data Access vs. OPC Alarm & Event OPC Data Access and OPC Alarm Event clients ar

Strany 6

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 14 2. Installation and Configuration 2.1. ‘Log on as a Service’ privilege The server runs as a Wind

Strany 7 - Figures

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 15 2.2. Installing the OPC Server The TrustedTMOPC Server must be installed and configured before O

Strany 8 - Tab l e s

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 16 2.3. Running the server Application The server will start automatically when a client requests a

Strany 9 - Disclaimer

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 17 2.4. Configuring the OPC Server Since the server runs as a Windows service it has no direct user

Strany 10 - Associated Documents

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 18 2.4.2. Selecting a server If the OPC Server is running on the same computer as the Setup progr

Strany 11 - 1. Description

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 19 The Error Log is displayed on the Log tab. The Error Log File setting specifies the file that wi

Strany 12 - OPC Architecture

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 2 Issue Record Issue Number Date Revised by Technical CheckAuthorised by Modification 1

Strany 13 - OPC T8030S

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 20 2.4.4. Controllers Controllers for the server are the TrustedTM Controllers on the system. Thes

Strany 14 - 2.1.1. Windows 2000 and XP

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 21 The Controller Name is the user-defined name that identifies the controller. The name is used t

Strany 15

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 22 The Comms ID number specifies the node address to use when communicating with the controller. I

Strany 16 - 2.3.1. Windows 2000 and XP

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 23 Using a low bandwidth connection (e.g. radio link, multiplexed fibre connection) will reduce the

Strany 17 - 2.4.1. Logging On

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 24 2.4.6. Users Select the Users tab to display a list of the current user names available, as show

Strany 18 - 2.4.3. System Preferences

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 25 2.6. Configuring the IEC 1131 Application 2.6.1. Update Types The OPC Server receives tag update

Strany 19

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 26 2.7. Reserved Variables The OPC Server provides summary data on each Controller. The tagnames b

Strany 20 - 2.4.4. Controllers

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 27 2.8. Configuring the PC 2.8.1. Real-time Clock The date and time settings for the TrustedTMcontr

Strany 21

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 28 3. Operation 3.1. Communication with the TrustedTM Controller When the OPC Server is configured

Strany 22

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 29 3.2.2. Error Log This function is used for debugging purposes. The Log tab displays the last 10

Strany 23

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 3

Strany 24 - Controller

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 30 3.2.3. Monitor Facility The Configuration tool allows monitoring of points from the Monitor tab.

Strany 25 - 2.6.3. Read/Write Timing

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 31 4. Suggested Network Configurations The following diagrams show the suggested network configurat

Strany 26 - 2.7. Reserved Variables

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 32 4.2. Single Graphics / Dual Ethernet This configuration has a single Graphics Station that runs

Strany 27 - 2.8. Configuring the PC

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 33 4.3. Multiple Graphics / Single Ethernet This configuration has a single server that runs the OP

Strany 28 - 3. Operation

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 34 4.4. Multiple Graphics / Dual Ethernet This configuration can be used for dual redundant DCS sys

Strany 29 - 3.2.2. Error Log

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 35 4.5. Example IP Address allocation These addresses are allocated to ensure that there are no cla

Strany 30 - 3.2.3. Monitor Facility

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 36 5. DCOM Configuration The OPC Server can be used in a configuration with the server and client o

Strany 31

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 37 Display the Properties of My Computer. Select the Default Properties tab, check the “Enable Dis

Strany 32

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 38 Select the Default COM Security tab (see Figure 20) This is Default Security in 2000 and COM S

Strany 33

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 39 Press the Access Permissions, Edit Default button. 2000: add the group ‘Everyone’ and give acces

Strany 34

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 4 This page intentionally blank

Strany 35

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 40 Press the Launch Permissions, Edit Defaults button. 2000: add the Everyone group and allow Defau

Strany 36 - 5. DCOM Configuration

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 41 For Windows XP SP2 only, select the Access Permissions - Edit Limits button. Set both ANONYMOUS

Strany 37

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 42 For Windows XP SP2 only, select the Launch and Activation Permissions - Edit Limits button. Set

Strany 38

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 43 XP service pack 1 and 2: Select My Computer, DCOM Config, locate the OPC Server(s) in the list

Strany 39

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 44 For both the Trusted OPC Server and Trusted OPC Event Server (if both are visible), configure th

Strany 40

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 45 Select the Identity tab and select “The system account (services only)” radio button (see Figure

Strany 41

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 46 If configuring a workgroup to use DCOM, the OPCEnum properties must be set. In the DCOM Config f

Strany 42

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 47 6. OPC Registry Details This information is required for some clients to allow them to recognise

Strany 43

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 48 7. Specifications Throughput per second Data Access Only (assuming all addresses are contiguou

Strany 45

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 5 Table of Contents 1. Description...

Strany 46

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 6 3.2. Monitoring the OPC Server...

Strany 47 - 6. OPC Registry Details

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 7 Figures Figure 1 Communication Path for TrustedTMOPC ...

Strany 48 - 7. Specifications

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 8 Tab l e s Table 1 Recommended Address Ranges .....

Strany 49

TrustedTM OPC T8030S Issue 23 April 10 PD-T8030S 9 Notice The content of this document is confidential to ICS Triplex Technology Ltd. companies and

Komentáře k této Příručce

Žádné komentáře