Troubleshooting the Drive
10-11
10.2.7 Problem: Drive Will Not Reverse Motor
Direction
.
10.2.8 Problem: Drive Does Not Power Up
Table 10.7 – Problem: Drive Will Not Reverse Motor Direction
Cause(s) Indication Corrective Action
Digital input is not selected
for reversing control.
None Check Digital Inx Sel. Choose
correct input and program for
reversing mode.
Digital input is incorrectly
wired.
None Check input wiring.
Motor wiring is improperly
phased for reverse.
None Switch two motor leads.
Reverse is disabled. None Check Reverse Disable
(A095).
Cause(s) Indication Corrective Action
No input power to the drive. None Check the power circuit.
Check the supply voltage.
Check all fuses and
disconnects.
Jumper between I/O
Terminals P2 and P1 not
installed and/or DC Bus
Inductor not connected.
None Install jumper or connect DC
Bus Inductor.