Chapter 2 Manage event tasks
Example – axis registration trigger
In a line that packages candy bars, you have to make sure that the perforation
occurs in the correct location on each bar.
Each time the registration sensor detects the registration mark, check the
accuracy of an axis and perform any required adjustment.
Due to the speed of the line, you have to arm the registration input within
the event task.
A registration sensor is wired as registration input 1…
…for the axis named Axis_1.
This event task interrupts all other tasks.
The following logic arms and re-arms the registration input.
Continuous task
If Arm_Registration = 1 (system is ready to look for the registration mark) then
the ONS instruction limits the EVENT instruction to one scan.
the EVENT instruction triggers Task_1 (event task).
50 Rockwell Automation Publication 1756-PM005-EN-P - October 2014