Installation Instructions
Bulletin 873P Ultrasonic Proximity Sensor
IMPORTANT: Save these instructions for future use.
IMPORTANT: Solid state devices can be
susceptible to radio frequency (RF)
interference depending on the
power and the frequency of the
transmitting source. If RF
transmitting equipment is to be used
in the vicinity of the solid state
devices, thorough testing s hould be
performed to assure that transmitter
operationisrestrictedtoasafe
operating distance from the sensor
equipment and its wiring.
ATTENTION: If a hazardous condition ca
result from unintended operation of this
device, access to the sensing area should
be guarded.
Description
Bulletin 873P Ultrasonic Sensors are self-contained
solid-state devices designed for noncontact sensing of solid
and liquid objects. They are available in several sensing
ranges with either an analog or discrete output depending
on the model.
The discrete output models have a normally open PNP
output that is switched when the target is within range.
They have a four-turn potentiometer to adjust the far limit of
the sensing range in order to ignore background targets.
The analog output models provide an output current or
voltage that varies linearly with the target distance within its
specified sensing range. Analog models are equipped with
either 4--20mA or 0--10V DC outputs. These devices can be
useful for many applications including: level monitoring,
diameter measurement, distance measurement, and web
tension.
873P Models
Sensing
Range
mm (inches)
Output Configuration
PNP
Normally Open
4to20mA 0to10VDC
100to600
(3.94to23.62)
873P- DBNP1- F4 873P- DBAC1- D4 873P- DBAV1- D4
200to1500
(7.87to59.06)
873P- DBNP2- F4 873P- DBAC2- D4 873P- DBAV2- D4
300to2500
(11.81 to
98.43)
873P- DCNP1- D5 873P- DCAC1- D5 873P- DCAV1- D5
Specifications
Discrete
Analog
Current
Analog
Voltage
Output
Configuration
Normally Open,
PNP
4to20mA 0to10VDC
Load Current <500mA —
Leakage Current <0.5mA —
Current
Consumption
<35mA
Operating Voltage 18 to 30V DC
Voltage Drop <3.5VDC —
Repeatability 0.2%
Hysteresis 2.5% typical —
Linearity —
0.3
Ultrasonic
Frequency
130, 180, 300kHz
Ultrasonic
Beam Angle
8_
Short Circuit
Protection
Incorporated
Overload Protection Incorporated
False Pulse
Protection
Incorporated
Transient Noise
Protection
Incorporated
Reverse Polarity
Protection
Incorporated
Approvals cULus listed and CE marked for all applicable
directives
Housing Material Plastic -- PBT
Enclosure Rating IP67
Connection Micro quick-disconnect (18mm discrete models have
12 inch pigtail)
Output LED Yellow —
Adjustment Potentiometer —
Operating
Temperature
--15 to 70_C(5to158_F)
Shock 30g, 11ms
Vibration 55Hz, 1mm amplitude, 3 planes
Komentáře k této Příručce