Chapter 10
Loading CVIM / USERPAK Configurations
10 3
In order to load the configuration in this case, you must first adjust your
current working configuration to free up the required memory space.
The procedure for loading a portion of a configuration will depend on which
portion you want to load, and where it is stored.
For example, suppose you want to reconfigure the Color CVIM module,
using the Viewports / Serial Ports portion of a previous configuration as a
basis for the viewports in the new configuration. Consider the two cases
below:
If the previous configuration is stored internally, you could simply select
Load Config. (Int), and then select the Viewports / Serial Ports item to
load that portion of the stored configuration. You could then select Load
Default Config, and then select the Menus and Inspection items to load
those portions of the default configuration. This would combine the
stored Viewports / Serial Ports configuration with the default Menus
and Inspection configurations.
If the previous configuration is stored on a memory card, you would first
load the configuration from the memory card (the memory card
configuration would then become the Color CVIM modules current
working configuration). Then you could load the Menus and Inspection
portions of the default configuration; in this way, the Viewports / Serial
Ports portion of the memory card configuration is preserved for use in
the new configuration.