Publication IASIMP-QS015C-EN-P - August 2011 85
ArmorStart Local Control Configuration Chapter 4
Network Input 0 Logic
If there is an IO Connection fault, manual operation from a pendant station or other push buttons will be
allowed. In this example, input 1 of the Boolean OR gate is used for the PLC control. In manual control,
input 0 could be from a sensor on a conveyor belt in which after manually starting the conveyor using a
pendant station, the product will pass the sensor. After a user selected count, the conveyor motor will stop
until another start command is given. Multiple sensors can be used along with logic to start and stop the
motor.
Input 1 Logic
The program also shows one of the ways in which a fault or trip can be programmed via the DeviceLogix
program. For example, a flashing stack light can be an indication of a fault or trip.
Flashing Stack Light Logic